Toshiba IK-TF9C Manuale Utente

Pagina di 32
15
(1. 3) Changing each setting in E.TRG mode
The E.TRG has four modes; 1P SNR, 1P SR, PW SNR, PW SR.
First set the "
" to MODE and select E. TRG, then set the "
" to E.TRG and select the desired E.TRG mode.
(1. 3. 1) Changing each setting in 1P SNR mode
(a) Changing the polarity of inputting trigger pulse setting
1
Set the "
" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2
Select either
 by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SNR exposure time setting
1
Set the "
" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
2
Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
(c) Changing the partial scanning setting
1
Set the "
" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2
Select either OFF/30fps/40fps/E.30fps/E.40fps by pushing [DATA UP], [DATA DOWN] buttons.
-- SHUTTER --
MODE
E.TRG
E.TRG
1P SNR
TRG.P
EXP.
50ms
PART
OFF
<MODE = E.TRG   E.TRG = 1P SNR>
• E.TRG  mode
• Partial scanning switch
     OFF/30fps/40fps/E.30fps/E.40fps
1P SNR, 1P SR, PW SNR, PW SR
0.01 ms       0.02 ms       0.4 ms       1 ms       20 ms       50 ms
0.01 ms
step
0.02 ms
step
0.1 ms
step
1 ms
step
2 ms
step
•  Input trigger pulse setting at 1P SNR and 1P SR
Input trigger pulse : positive polarity
•  Exposure time setting at 1P SNR and 1P SR
• Sutter mode   MANU, SS, E.TRG
Input trigger pulse : negative polarity
Move up down 
By pushing 
MENU UP, DOWN
Set by pushing
DATA UP, DOWN