4-1    Symptoms and Confirmation 
Check the following items. If any abnormality is found, consult the dealer from whom you 
purchased this product or our nearest branch/office. 
  
Symptom 
Possible cause/ remedy 
No image is displayed. 
• The cable is not correctly connected. 
• The AC adapter is disconnected from the wall outlet. 
• The AC adapter is disconnected from the power supply socket 
of the unit. 
• The power is not ON. (Blue light) 
• Zoom is set at the TELE side, displaying only the white/black 
part of the document. 
• If you turn the power ON immediately after turning it OFF, the 
unit may not start. Wait for several seconds after turning the 
power OFF, and then turn it back ON. 
• The slide switch is not set to the correct image output 
(RGB/HDMI). Set the “RGB/HDMI Switch” correctly.     
• Reconnect the AC adapter. 
The output image (resolution) 
changes automatically. 
• When the HDMI monitor is connected, the output image 
(resolution) is automatically changed based on information 
from the connected monitor. 
No image is displayed from 
the USB. 
• No image is output from USB when USB mode is set to mass 
Storage or in Play mode or in Recording mode or when using 
the Compare Picture Function. Switch the USB mode from 
Mass Storage to Application by referring to [       (Setting)] 
> [            ] on the touch panel. When using Play mode, 
change the output image to Camera image. 
The image is out of focus. 
• The document (object) is too close to the lens. Move the 
document (object) slightly away from the lens. 
• Auto focus may have difficulty in adjusting correctly. Focus on 
an image manually by referring to “Manual focus”. 
The image is too dark. 
• The intensity of the lighting is insufficient. Tap  [   (Main 
menu)]>[    ]on the touch panel or press the [      ] 
button on the remote control to adjust the brightness.