DIAGNOSTICS 
28 
CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL
 
 
 
Long Test Without Loopback 
This group of tests are entered by pressing the select switch only while powering up  the 
unit with the on/off switch. All equipment should be disconnected from the unit prior to 
running this test. 
Test 1 
- EPROM program checksum test is the same as described previously. 
Test 2
 - Dynamic ram test checks the dynamic ram more extensively than the short test 
or the power up test. The test takes longer to perform. If this test fails (ERROR LED and 
LED #2 are lit) then the unit must be serviced. Other LEDs #5-#8 may also be lit 
indicating the amount of memory that is installed. 
The failing board and memory device can be determined by pressing the advance 
switch. The MODE LED will be lit if the failing board is the base mother board or the 
bottom-most memory board installed. The DATA LED will be lit if the failing board is the 
second from the bottom. The BUSY LED will be lit for the third board, and the ERROR 
will be lit for the fourth board. The LEDS 1-8 correspond to the physical placement of the 
failing chip. If the failing chip is the one all the way to the left, then LED 1 will be lit. If the 
failing chip is the one all the way to the right, then LED 8 will be lit. The chips in the 
middle correspond appropriately. Hitting the select switch will retry the test. In order to 
bypass this test completely, both the advance and the select switches must be pressed. 
Test 3 
- Same as static ram read/write test above 
Test 4
 - Same as non-volatile ram checksum test above 
Test 5
 - Port addressing test checks if the contents of non-volatile memory agree with 
the port configuration. If this test fails (ERROR LED and LED #5 are lit) then the 
configuration memory has been corrupted or a port communication chip has failed. 
Reload the factory default settings as described below and retry the test. Make sure 
there are no cables connected to the caretaker Plus. Re-run the test, if the test still fails 
then the unit must be serviced. The advance switch may be pressed to determine which 
port is the failing port.  The MODE, DATA, and BUSY LEDs will be lit. The LEDs of all 
ports which pass will be lit (ERROR led is used for port 0). A failing port will have its 
corresponding LED off. The select switch may be pressed to execute the test again. In 
order to bypass this test completely, both the advance and the select switch may be 
pressed. 
Test 6 
- Module test ensures that there are no signal shorts on a port, in order for this 
test to pass, no equipment should be connected to the Caretaker Plus. If this test fails 
(ERROR LED and LED B6 are lit) then a port communication chip has failed and the unit 
must be serviced. 
The advance switch may be pressed to determine which port is the failing port. MODE, 
DATA, and BUSY will all be flashing. The LEDs or all ports which pass will be flashing 
(ERROR LED is used for port 9). A failing port will have its corresponding LED steadily 
lit. Ports not installed will have their corresponding LEDs off. The select switch may be 
pressed to execute the test again. In order to bypass this test completely, both the 
advance and the select switches may be pressed.