Sanyo HR-AAUL Dépliant
Size : AA
1450mAh
1300mAh
1.2V
Fast Charge
2)
1450 mA x about 1.1h
Charge
Condition
Condition
Fast Charge
2)
0°C - 40°C
0°C - 50°C
Less than
30days
30days
-20°C - 50°C
Less than
90days
90days
-20°C - 40°C
Less than
1year
1year
-20°C - 30°C
About 27 g
14.2(D) x 49.0(H) mm
Typical Characteristics
Charge
Discharge
1)Single cell capacity under the following condition.
Dimensions
(with tube)
Specifications
Cell Type HR-AAUL
Charge : 145mA×16h, Discharge : 290mA(E.V.=1.0V) at 20°C
Nominal Voltage
Discharge Condition
Weight
4)
Size
4)
:(Diameter) x (Height)
Type : Nickel-Metal Hydride Battery
Internal Impedance
3)
(after discharge to E.V.=1.0V)
Charging Current x Time
D
H
14.2 mm
49.0 mm
2)Use recommended charging system.
3)After a few charge and discharge cycles under the above 1) condition.
4)With tube.
3)After a few charge and discharge cycles under the above 1) condition.
4)With tube.
49.0 mm
Ambient Temp.
Storage
Condition
Condition
14.2 mm
Capacity
1)
Typical
Minimum
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
0
200 400 600 800 1000 1200 1400 1600 1800
Discharge Capacity (mAh)
Cell Voltage (V)
Charge : 1200mA (-
∆
V=10mV)
Rest : 1h
Discharge : 240mA, 1200mA, 2400mA (E.V.=1.0V)
Ambient Temp. : 20°C
Discharge : 240mA, 1200mA, 2400mA (E.V.=1.0V)
Ambient Temp. : 20°C
240mA
1200m
2400mA
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
0
10
20
30
40
50
60
70
80
90
Charge Time (min)
Cell Voltage (V)
Charge : 1200mA (-
∆
V=10mV)
Ambient Temp. : 0°C,20°C,40°C
0°C
20°C
40°C
About 25mΩ(at 1000Hz)