Toshiba ik-tf7u Manuale Utente

Pagina di 36
17
-- SHUTTER --
MODE
E.TRG
E.TRG
1P SR
TRG.P
EXP.
30ms
PART
OFF
0.01 ms       0.02 ms       0.4 ms       1 ms       20 ms       30 ms
<MODE = E.TRG   E.TRG = 1P SR>
• E.TRG mode
• Partial scanning switch
     OFF/40fps/50fps/60fps/70fps/80fps/90fps/
     E40fps/E50fps/E60fps/E70fps/E80fps/E90fps 
1P SNR, 1P SR, PW SNR, PW SR, RR
• Input trigger pulse setting at 1P SNR and 1P SR
• Exposure time setting  at  1P  SNR  and  1P  SR
• Sutter mode   MANU, SS, E.TRG
Input trigger pulse : positive polarity
Input trigger pulse : negative polarity
Move up down 
by pushing 
MENU UP, DOWN
Select the desired
value by pushing
DATA UP, DOWN
0.01 ms
step
0.02 ms
step
0.1 ms
step
1 ms
step
2 ms
step
(1. 3. 2)
Changing the setting in 1P SR mode
(a) Changing the polarity of inputting trigger pulse setting
1
Move the "
" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2
Select either 
,  
 by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SR exposure time setting
1
Move the "
" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
2
Select the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
(c) Changing the partial scanning setting
1
Move the "
" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2
Select the mode by pushing [DATA UP], [DATA DOWN] buttons.