Toshiba ik-tf7u Manuale Utente

Pagina di 36
29
( 5 )   RR (Reset restart)
Input of an external reset-restart signal (CC4 of the DIGITAL terminal: External VD input) permits one screen
of information to be output at an arbitrary timing.
(5. 1) Long Term Exposure
When a sufficient sensitivity is not obtained with the normal operation conditions or capturing the trial of a
moving subject is desired, the reset-restart function allows high-sensitivity images by extending the exposure
time. To achieve this, please input from an external source a VD signal that has an expanded VD pulse and VD
pulse interval.
(5. 2) Input Timing Chart Example
External HD IN
External VD IN
(Internal VD)
About 1H
V reset
Exposure period
External VD interval: more than 1 frame
Exposure period
Exposure period
About 1H
V reset
1 frame=  796H (Partial scanning OFF)
                580H (Partial scanning 40fps)
                465H (Partial scanning 50fps)
                387H (Partial scanning 60fps)
                332H (Partial scanning 70fps)
                290H (Partial scanning 80fps)
                258H (Partial scanning 90fps)
RGB data 
(video interval image)
FVAL
LVAL, 
DVAL
1 frame