Cateye CC ST-200 Dépliant

Pagina di 2
#169-6160/#169-6165
Bracket Sensor Kit/(Long)
#169-6168
Bracket Sensor Kit for Aero Bar
#169-6167
Center Mount Bracket Kit
#169-6169
Bracket Sensor Kit for Aero Bar
#169-9731
Heavy Duty Wire and Bracket Sensor Kit
#169-6170
Attachment Kit
#169-6280
Universal Sensor Band
#166-5120
#169-6180
Wheel Magnet
Lithium Battery (CR1620)
Setting Values Cross Reference Table 
(The tire size is marked on both sides of the tire.)
CO.,LTD.
U.S. Pat. Nos. 4636769/4642606/5236759/5226340/5264791
and Design Patented
Copyright©  1996  CATEYE Co., Ltd.
CCMST2-970214 Printed in Japan  0687261   
3
CATEYE TOMO
CYCLOCOMPUTER
Model CC-ST200
TIRE SIZE
TIRE SIZE
TIRE SIZE
20 x 1.75
150
26 x 1.40
200
650 x 38B
211
24 x 1
175
26 x 1.50
199
700 x 18C
207
24 x 3/4 Tubular
178
26 x 1.75
202
700 x 19C
209
24 x 1-1/8 Tubular
179
26 x 1.95
205
700 x 20C
209
24 x 1-1/4
191
26 x 2.00
206
700 x 23C
210
24 x 1.75
189
26 x 2.1
207
700 x 25C
211
24 x 2.00
192
26 x 2.125
207
700 x 28C
214
24 x 2.125
196
26 x 2.35
208
700 x 30C
217
26 x 1(559mm)
191
27 x 1
215
700 x 32C
216
26 x 1(650c)
195
27 x 1-1/8
216
700C Tubular
213
26 x 1.25
195
27 x 1-1/4
216
700 x 35C
217
26 x 1-1/8 Tubular
197
27 x 1-3/8
217
700 x 38C
218
26 x 1-3/8
207
650 x 35A
209
700 x 44C
222
26 x 1-1/2
210
650 x 38A
212
TROUBLE SHOOTING
The following situations do not indicate malfunction of the cyclocomputer. Check the
following before taking to repair.
*
When current speed does not appear, short-circuit the contact on the back with metal.
The unit will function normally if the speed display appears.
Display response is slow.
----- Is it at a low temperature under 32
°
F(0
°
C)?
----- It returns to normal state when temperature rises.
No display.
----- Has the Lithium Battery in the main unit worn out?
----- Replace the Lithium Battery with a new one.
Incorrect data appear.
----- Execute "All Clear" operation.
Current speed does not appear.
----- Is there anything on the contact of the main unit or of the bracket?
----- Wipe the contact clean.
----- Is the distance between sensor and magnet too far?
----- Are the marking line of the sensor and the center of magnet matched each other?
----- Refer to "Sensor/Magnet Mounting" and re-adjust correctly.
----- Is the wire broken?
----- Replace the Bracket & Sensor part with a new one.
Transmission signal loss in damp or wet conditions.
----- Water or condensation may collect between the bracket sensor and the computer causing an
interruption in the data transmission. Wipe the contacts with dry cloth. Contacts can also be
treated with a water repellent silicon jell from an automotive parts or hardware store. Do not use
industrial water repellent; it may damage the bracket.
When the S/S button is pressed, the unit doesn't activate or stop.
----- Is the unit in the Auto function?
----- The S/S button doesn't function in the Auto function.
MAINTENANCE/PRECAUTIONS
• Do not leave the main unit exposed to direct sunlight when the unit is not in use.
• Do not disassemble the main unit, sensor and magnet.
• Don't pay too much attention to your computer's functions while riding!  Keep your eyes on the
road and duly consider to traffic safety.
• Check relative position of sensor and magnet periodically.
• For cleaning, use neutral detergent on soft cloth, and wipe off later with dry cloth. Do not apply
paint thinner, benzine, or alcohol, to avoid damages on the surface.
• If there is mud, sand or the like clogs between the button and the body, the movement of the
button may be disturbed. Softly wash away such objects with water.
SPECIFICATIONS
Applicable Cycle Sizes
130cm - 229cm
Applicable Fork Diameter
11ø - 36ø  (S:11 - 26ø  L:21 - 36ø)
The length of the wire
70cm
Power Supply
Lithium Battery (CR1620/CR1616) x 1
Battery Life
Approx. 3 years(The life of the first factory-loaded battery may
be shorter than this period.)
Dimension/Weight
1-15/16" x 1-25/32" x 5/8" (49 x 45 x 16 mm) / 0.74 oz (21 g)
Controller
4-bit 1-chip Microcomputer (Crystal Controlled Oscillator)
Display
Liquid Crystal Display
Sensor
No Contakt Magnetic Sensor
Operating Temperature Range
0
°
C - 40
°
C(32
°
F - 104
°
F)
*
The specifications and design are subject to change without notice.
LIMITED WARRANTY
1-Year Warranty for Main Unit Only
(Accessories/Attachments and Battery Consumption excluded)
If trouble occurs during normal use, the part of the Main Unit will be repaired or replaced free of charge. The service must be
performed by Cat Eye Co., Ltd. To return the product, pack it carefully and remember to enclose the warranty certificate with
instruction for repair. Please write or type your name and address clearly on the warranty certificate. Insurance, handling and
transportation charges to our service shall be borne by person desiring service.
(Address for service)
2-8-25, Kuwazu, Higashi Sumiyoshi-ku, Osaka 546 Japan
Attn.: CAT EYE Customer Service Section
Service & Research Address for United States Consumers:
CATEYE Service & Research Center
1705 14th St. 115 Boulder, CO 80302
Phone:
303-443-4595
Toll Free:
800-5CATEYE
Fax:
303-473-0006
e-mail: CatEyeUSA@aol.com