Lucent Technologies 555-670-111 Manuale Utente
MERLIN LEGEND Communications System Release 7.0
System Programming
System Programming
555-670-111
Issue 1
April 1999
Programming Procedures
3-313
Computer Telephony Integration (CTI) Link
3
NOTES:
■
You should choose a module other than the one that has the system
programming port so that you can still perform maintenance and system
programming when the board with the CTI link extension is busied-out.
programming port so that you can still perform maintenance and system
programming when the board with the CTI link extension is busied-out.
■
Be sure to busy-out the board with the CTI link before starting any
programming activities.
programming activities.
When you add a CTI link, the system performs the following actions:
■
The programmed buttons for that extension revert to the factory settings for
a non-operator MLX telephone.
a non-operator MLX telephone.
■
Forwarding is deactivated to the extension.
■
The extension is removed from membership in calling groups.
■
The extension is removed from membership in coverage groups.
■
The extension is removed from membership in Service Observing groups,
or as an Observer of a Service Observing group.
or as an Observer of a Service Observing group.
■
The Extension Directory label for the extension is changed to CTILINK.
■
The factory setting for alarms is active on this link.
■
Dial access to pools is removed from the station.
NOTES:
■
Be sure to restore the board after finishing any programming activities.
■
If the primary and secondary cover buttons are not removed, the
following message appears on the programming device (SPM or
MLX-20L):
following message appears on the programming device (SPM or
MLX-20L):
CTI
Link
Extension
xxxx
added,
but
it
has
primary
or
secondary
cover
buttons
at
other
extensions.
Please
remove
them.
Exit