Honeywell 128BPTSIA Manuale Utente

Pagina di 80
 
 
– 54 – 
Using #77 Instant Activation Mode 
The #77 Instant Activation Mode is used to activate outputs, bypass zones, 
etc. immediately upon exiting the #77 Mode. The actions that may be 
activated are relay commands, arm/disarm commands, zone bypassing 
commands, and open/close access conditions. 
Relay Commands 
Action Code Action 
Specifier 
01  
Relay On 
Relay #  
02  
Relay Off 
Relay #   
03  
Relay Close for 2 seconds 
Relay #   
04  
Relay Close XX minutes 
✳ Relay 
05  
Relay Close YY seconds 
✳ Relay 
06  
Relay Group On 
Relay Group # 
07  
Relay Group Off 
Relay Group # 
08  
Relay Group Close for 2 seconds 
Relay Group # 
09  
Relay Group Close XX minutes 
✳ 
Relay Group # 
10  
Relay Group Close YY seconds 
✳ 
Relay Group # 
✳ Check with your installer for the amount of time. 
Arm/Disarm Commands 
Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices 
for automatic arming and disarming functions. 
"During" can be used to arm or disarm the control for a specific time only.  
For example, if "during" is selected with Arm-STAY, the system will 
automatically Arm-STAY at the beginning of the window and automatically 
disarm at the end of the window. 
Action Code Action 
Specifier 
20  
Arm-STAY 
Partition(s) 
21  
Arm AWAY 
Partition(s) 
22  
Disarm 
Partition(s) 
23  
Force Arm STAY (Auto-bypass faulted zns)  
Partition(s) 
24  
Force Arm AWAY (Auto-bypass faulted zns) 
Partition(s) 
25 Arm 
INSTANT 
Partition(s) 
26 Arm 
MAXIMUM 
Partition(s)