Page 34 
 
 
 
Z 1 TYPE THROUGH Z 48 TYPE 
 
 
This item specifies the zone type for each zone.  All choices are listed in this manual under DESCRIPTION OF ZONE TYPES. 
 
For zone types, the current setting is shown on the bottom line. 
 
 
 
 
 
 
 
ZONE 1 TYPE:          64 
 
 
 
AUXILIARY       #=CHNG 
↕  
 
THROUGH 
 
 
 
 
ZONE 48 TYPE:         64 
 
 
 
AUXILIARY       #=CHNG 
↑ 
 
To change a zone type, press the ' # ' key, then use the arrow keys to scroll through the list of zone types.  Press the ' # ' key to 
select a new type
.
  The display shows: 
 
 
 
 
SELECT TYPE:           1 
 
 
 
PERIMETER              
 
 
ZONE RESPONSE TIME 
 
All zones, in the Omni II are set to a 300 millisecond fixed response time.
 
 
ZONE TYPES 
 
ZONE TYPE 
NUMBER 
DESCRIPTION 
 
ENTRY/EXIT 
   0 Entry/Exit 
PERIMETER 
   1 Perimeter 
NIGHT 
INT 
   2 Night 
Interior 
AWAY 
INT 
   3 Away 
Interior 
2X ENTRY DELAY 
 
 
Double Entry Delay  
4X ENTRY DELAY 
 
 
Quadruple Entry Delay  
LATCH 
PERIM 
   6 Latching 
Perimeter 
LATCH NIGHT INT 
 
 
Latching Night Interior 
LATCH 
AWAY 
INT 
  8 Latching 
Away 
Interior 
PANIC   
 
 
 
16 
Panic 
POLICE 
EMERG   17 
Police 
Emergency 
SILENT 
DURESS   18 
Duress 
TAMPER    19 
Tamper 
LATCH 
TAMPER   20 
Latching 
Tamper 
FIRE 
 
 
 
 
32 
Fire 
FIRE 
EMERG 
   33 
Fire 
Emergency 
 
GAS 
 
 
 
 
34 
Gas Alarm                                       
AUX 
EMERG 
   48 
Auxiliary 
Emergency 
TROUBLE 
   49 
Trouble 
FREEZE    54 
Freeze 
WATER  
 
 
 
55 
Water 
FIRE 
TAMPER 
   56 
Fire 
Tamper 
AUXILIARY 
   64 
Auxiliary 
KEY 
SWITCH 
   65 
Keyswitch 
Input 
ENERGY SAVER 
 
 
80 
Programmable Energy Saver Module 
OUTDOOR 
TMP   81 
Outdoor 
Temperature 
TEMPERATURE   82 
Temperature 
TEMP 
ALARM 
   83 
Temperature 
Alarm 
HUMIDITY 
   84 
Humidity