Home Automation 20A00-1 Manuale Utente

Pagina di 68
 
Page 49 
 
 
 
SETUP EXPANSION 
 
To configure each Expansion Module that is installed on your system, from the Installer Setup menu, press the 7 (EXP) key. 
 
Expansion Modules include Hardwire Zone Expanders, ALC Interface Modules, and Serial Interface Modules using either the 
Omni-Link or Pro-Link Protocol. 
 
MODULE 1 TYPE 
 
The Module Type defines the function of each expansion module on the controller.  Module 1 is the module with the ADDR 
jumper set to 1.  Set the module type from the list below.  Press ' # ' to change the module type, then use the arrow keys to select 
the proper module type, then press ' # ' to enter. 
 
 
MODULE 1 TYPE          1 
 
 
 
NOT USED        #=CHNG 
 
 
Select from the following for the module with jumper set to 1: 
 
MODULE TYPES 
NUMBER 
DESCRIPTION 
 
NOT 
USED 
   0 No 
module 
is 
installed 
HARDWIRE EXPNDR   
 
Model 10A06 Hardwire Expander installed 
ALC 
    2 ALC 
Interface 
Module 
is 
installed 
OMNI-LINK 
 
 
 
Model 10A17 Serial Interface using the Omni-Link protocol 
PRO-LINK 
 
 
 
Model 10A17 Serial Interface using the Pro-Link protocol 
 
Notes:  
 
1.  Only 2 Model 10A06 Hardwire Expander Modules can be installed.  When a Wireless Receiver is configured, only 1 
Hardwire Expander Module can be installed. 
 
2.  Only 1 Serial Interface Module can be installed and configured (Omni-Link or Pro-Link).  To configure the protocol for the 
built-in serial port, set the "Serial 1 Function" to the desired protocol. 
 
MODULE 2 TYPE - MODULE 4 TYPE 
 
Module 2 is the module with the jumper set to 2, and so on.  Set each module type from the list above.
 
 
SERIAL 1 RATE 
 
"Serial 1 Rate" selects the baud rate used for the built-in serial interface (J1 Serial) on the Omni II controller.  Select the baud rate 
for the built-in serial interface from the list.  Use the arrow keys to select the baud rate then press the ' # ' key. 
 
 
BAUD RATE  NUMBER 
 
  
    75 baud 
 
  150 baud 
 
  300 baud 
 
  600 baud 
 
1200 baud 
 
2400 baud 
 
4800 baud 
 
9600 baud 
(default)