Home Automation 20A00-1 Manuale Utente

Pagina di 68
 
 
Page 55 
 
 
APPENDIX A – CONTACT ID REPORTING FORMAT 
 
 
ZONE TYPE 
TRIP 
TROUBLE
DESCRIPTION 
 
 
 
 
Entry/exit (also Double & Quad) 
134 
370 
Entry/exit burglary 
Perimeter (also Latching) 
131 
370 
Perimeter burglary 
Night Interior (also Latching) 
132 
370 
Interior burglary 
Away Interior (also Latching) 
132 
370 
Interior burglary 
Panic 120 
375 
Panic 
alarm 
Police Emergency 
120 
375 
Panic alarm 
Silent Duress 
122 
375 
Silent panic 
Tamper (also Latching) 
137 
370 
Tamper burglary 
Fire 110 
373 
Fire 
alarm 
Fire Emergency 
110 
373 
Fire alarm 
Gas 151 
373 
Gas 
alarm 
Auxiliary Emergency 
150 
370 
24 hour non-burglary 
Trouble 
330 
330 
System peripheral trouble 
Freeze 
159 
370 
Low temperature alarm 
Water 154 
370 
Water 
leakage 
Auxiliary none 
none 
none 
Fire tamper 
321 
321 
Bell/siren #1 trouble 
Temperature Alarm 
152 
370 
Refrigeration alarm 
 
EVENT CODE 
DESCRIPTION 
 
 
 
Zone bypass/restore 
570 
Zone bypass/restore 
Fire zone bypass/restore 
571 
Fire bypass/restore 
Automatic communicator test 
602 
Periodic test 
Cancel 406 
Cancel 
User disarm/arm 
401 
Open/close by user 
Programmed disarm/arm 
403 
Automatic open/close 
PC Access disarm/arm 
407 
Remote open/close 
Quick arm 
408 
Closing-quick arm 
Keyswitch disarm/arm 
409 
Keyswitch open/close 
 
SYSTEM TROUBLE 
CODE 
DESCRIPTION 
 
 
 
Battery low 
302 
Low system battery 
Fuse 
312 
Power supply overcurrent 
AC power failure 
301 
AC power loss 
Phone line dead 
351 
Phone line #1 trouble 
Digital communicator 
350 
Communication failure 
Fire tamper 
321 
Bell/siren #1 trouble