Crimestopper Security Products TN-4004 Manuale Utente

Pagina di 12
 
10 
WIRING
 
 
Pin 12 Orange: Alarm Trigger (-) Default* 
or Door Open/Close  Input #1  
A. Alarm Trigger*: Triggers alarm input of tracking device if received a negative 
input for 15 seconds or longer. This is connected to the negative siren output, if 
alarm has positive siren output use a relay to convert to negative.  
 
B. Door Open/Close  Input :This unit can be programmed for monitoring of door 
open and close. This configuration must be program see dealer for 
programming instructions. 
 
Pin 13: Empty 
 
Pin 14 Red: 12 Volts Input 
This wire is the main power lead. It requires 12 volts constant power. 
 
Pin15 Black: Chassis Ground Input 
THIS WIRE MUST BE CONNECTED TO THE CHASSIS METAL OF THE VEHICLE.  
Scrape away any paint or dirt to ensure a good connection. 
 
Pin 16 Black Ground Input 
This wire is ground input from the back up battery. 
 
Pin 17 Gray (Not Used) 
 
Pin 18 White/Brown (-) Output 
This wire can be programmed to be a ½ second pulsed output or a 3 second pulsed 
output. 
 
Pin 19 Green/Yellow (-) Input 
Ground this wire to trigger start up test on unit 
 
PIN 20 White/Yellow (Not Used)