Elmo DSP 402 Manuale Utente

Pagina di 116
 
Data description: 
Value Description 
-32,768…-1 Manufacturer 
specific 
Disable drive function 
Slow down on slow-down ramp; disable drive function 
2…32,767 Reserved 
  An attempt to set an unsupported value causes the transmission of abort code 
0609 0030, value exceeded. 
ld be taken in case of the transition: 
OPERATION ENABLE => SWITCHED ON. 
 
Object description: 
Index 605Ch 
Object 0x605C: Disable operation option code  
This parameter determines which action shou
Name 
Disable operation option code 
Object code 
VAR 
Data type 
INTEGER16 
Category Optional 
 
Entry description: 
Access Read/write 
PDO mapping 
No 
Value range 
INTEGER16 
Default value 
 
Data description: 
Value Description 
-32,768…-1 Manufacturer 
specific 
Disable drive function 
Slow down on slow-down ramp and then disable drive function 
2…32,767 Reserved 
  An attempt to set an unsupported value causes the transmission of abort 
code 0609 0030: Value exceeded. 
CANopen DSP 402 Implementation Guide 
 
MAN-CAN402IG (Ver. 1.2) 
 
 
33