Avaya 03-300430 Manuale Utente

Pagina di 2574
IPSV-CTL (Ipserver Interface Control)
Issue 1 June 2005
1411
 
Error Log Entries
Whenever an IPSI interchange takes place, an error is logged against IPSV-CTL with a code 
that conveys information about the cause of the interchange and which IPSI became active. 
Use 
on page 1413 to help identify areas of the Alarm Log to investigate to 
find the source of the problem.
Error Codes for Software-Requested Interchanges
Table 504: Error Code Descriptions and Aux Data 
Error Code
Description
Aux Data
3wxyz
1
 for encoding of the wxyz digits of the error code.
Software requested IPSI interchange / control change
2
2. Control change is moving the Archangel’s functionality to or from the IPSI.
See 
50000
Craft demand interchange of IPSI to A side
See 
51000
Craft demand interchange of IPSI to B side
See 
60000
Daily interchange of IPSI to standby failed
0
61000
Daily interchange of IPSI back to previous active failed
0
Table 505: Encoding of Error Codes for Software Requested IPSI interchange 
Field
Variable Name
Value Description
w
Active IPSI post 
action
0
The A-side IPSI is active after the interchange.
1
The B-side IPSI is active after the interchange.
x
Control (Archangel) 
pre and post action
0
Control on IPSI before and after the interchange.
1
Not in IPSI control before and after the interchange.
2
Control leaves IPSI.
3
Control moves to IPSI.
 1 of 2