Avaya 03-300430 Manuale Utente

Pagina di 2574
Communication Manager Maintenance-Object Repair Procedures
1624 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Major Alarm Inquiry Test (#142)
The Major alarm raised by an MM710 Interface Media Module indicates that the average bit 
error rate on the DS1 facility is greater than 1/1000. The Major Alarm Inquiry Test is used to 
determine that the received DS1 bit error rate is greater than 1/1000. The MM710 Interface 
Media Module takes 10 seconds to recognize and report a Major alarm and 10 seconds to 
recognize and report that a Major alarm condition is cleared.
When the MM710 Interface Media Module detects a Major alarm, it sends a MAJOR-ALARM 
message to the maintenance software. (32-channel interfaces send a YELLOW alarm to the far 
end). After the maintenance software receives a MAJOR-ALARM message, the Major Alarm 
Inquiry Test is initiated to confirm the Major alarm on the MM710 Interface Media Module. The 
Inquiry Test runs every 10 minutes until the Major alarm is cleared. The maintenance software 
places all trunks or ports on the Media Module in the out-of-service state if the Major alarm 
persists for more than 20 minutes.
Any
NO
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board 
is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1 
location command to administer the MM710 interface if it is not 
already administered.
2. If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the 
board is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then enter 
the busyout board location command.
4. Enter the reset board location command.
5. Enter the release board location command.
6. Enter the test board location long command. 
This should re-establish the linkage between the internal ID and the port.
Table 595: TEST #141 Yellow Alarm Inquiry Test  (continued)
Error
Code
Test
Result
Description/ Recommendation
 6 of 6