Avaya 03-300430 Manuale Utente

Pagina di 2574
Communication Manager Maintenance-Object Repair Procedures
2044 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each appropriate test’s description, and follow its recommended 
procedures.
b. This error occurs when the active or standby SNC detects problems in its timing reference 
with an SNI circuit pack in the same carrier. The slot location of the SNI with which the SNC 
cannot communicate is given in the previous error table.
If duplicated SNCs exist in the carrier:
1. If the SNCs are duplicated in the carrier, use display errors to check the error log. If 
both SNCs have this error, replace the SNI that the SNCs are complaining about.
2. If the error occurred only on the standby SNC and the active SNC in the carrier does not 
have this error, use reset board to reset the standby SNC. Use status 
switch-node
 to show the active and standby SNCs. If the error returns after the 
standby has been reset, replace the standby SNC.
3. Retry the command. If this error is still in the error log, continue with the following steps.
4. If the active SNC has this error, use set switch-node-clock to set the standby SNC 
to active. If the new active SNC has this error, replace the SNI that the SNC is 
complaining about. Otherwise, replace the SNC that originally had this error.
If only one SNC exists in the carrier:
1. Replace the SNI that the SNC is complaining about.
2. Retry the command. If this error is still in the error log, continue with the following step.
3. Replace the SNC.
3585 (
Any
19
Failure audit (#777)
MAJ
OFF
test board location r 1
3841 (
Any
20
Failure audit (#777)
MAJ
OFF
test board location r 1
1. The slot location of the SNI with which the SNC cannot communicate.
Table 746: SNC Reference Error Log Entries  (continued)
Error
Type
Aux
Data
SNI
Slot
1
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
 2 of 2