Avaya 03-300430 Manuale Utente
Communication Manager Maintenance-Object Repair Procedures
2390 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2305
Any
Yellow Alarm Inquiry test
(#141)
WRN
MIN
OFF
test board location
2306
Any
Yellow Alarm Inquiry test
(#141)
WRN
MIN
OFF
test board location
2561
Any
Major Alarm Inquiry test
(#142)
WRN
MIN
OFF
test board location
2817
Minor Alarm Inquiry test
(#143)
WRN
MIN
OFF
test board location
3073 to
3160 (
3160 (
Any
Slip Alarm Inquiry test
(#144)
WRN
MIN
OFF
test board location
r 6
3330(
46083
WRN
MIN
ON
3585 to
3601 (
3601 (
Any
Misframe Alarm Inquiry
test (#145)
WRN
MIN
OFF
test board location
r 6
3840(
Any
None
3841(
4358
3842 (
)
46097
3843 (
)
46081
3900 (
Any
CPE Loop-Back Jack test
(#1212)
3901 (
)
Any
Far CSU Loopback test
(#1213)
3902 (
)
Any
One-Way Span test
(#1214)
3999 (
Any
None
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to the appropriate
test’s description, and follow its recommended procedures.
2. If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the circuit
pack, then a warning alarm is raised. The alarm is raised after the circuit pack has been missing for a
period of 15 minutes. Warning alarms are also raised against any ports administered on the circuit pack.
period of 15 minutes. Warning alarms are also raised against any ports administered on the circuit pack.
3. Minor alarms on this MO may be downgraded to Warning based on values on the set options screen.
4. Major alarms on this MO may be downgraded to minor or warning alarms based on values set on the set
options screen.
Table 852: DS1 Interface Circuit Pack Maintenance Error Log Entries (continued)
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
3 of 3