Avaya 03-300430 Manuale Utente

Pagina di 2574
Communication Manager Maintenance-Object Repair Procedures
444 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1003
ABRT
The system could not allocate a tone receiver for the test.  The system may 
be oversized for the number of Tone Detectors present or some Tone 
Detectors may be out-of-service.
1. Resolve any TTR-LEV errors in the Error Log.
2. Resolve any TONE-PT errors in the Error Log.
3. If neither condition exists, retry the command at 1-minute intervals up to 
5 times.
4. If the test continues to abort, escalate the problem.
1004
ABRT
A valid call seized the port during the test and aborted the test.
1. Use display port location to determine the station extension.
2. Use status station extension to determine the service state of 
the port.
3. If the port is active, wait until it is idle before testing.  Retry the 
command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1005
ABRT
This test was aborted due to a configuration problem.  The test is not 
applicable for this type of analog port.  This error can be ignored.
1018
ABRT
Administration has disabled the test.  The default for the Test field on the 
station screen is y.  Determine why this field has been set to n on this 
station (this may be due to the ringing application Test 48, which can be 
disturbing to customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change 
station extension.
2. Enter y in the Test field.
S8300
G700
 
1412
ABRT
This test does not execute on a G700 Media Gateway.
Table 131: Test #161 Analog Looparound Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 4