Avaya 03-300430 Manuale Utente
Communication Manager Maintenance-Object Repair Procedures
460 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1002
ABRT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to
on page 2237 Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to the
2. Look for TONE-PT errors in the Error Log. If present, refer to the
3. If neither condition exists, retry the test at 1-minute intervals a maximum
of 5 times.
1007
ABRT
The Announcement circuit pack thinks that Port 1 or Port 9 is busy.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, follow the Announcement Port
maintenance procedures for Ports 1 and 9.
1024
ABRT
Announcement circuit pack blocked the test because an announcement
download is in progress. If an announcement download is in progress,
status data-module <announcement data extension> should
download is in progress. If an announcement download is in progress,
status data-module <announcement data extension> should
show that the announcement data port is connected to a NETCON data
channel, and the "card-in-use" LED for the memory card should be on (to
determine the extension of the announcement data module, use list
data-module). See Note (
channel, and the "card-in-use" LED for the memory card should be on (to
determine the extension of the announcement data module, use list
data-module). See Note (
) at end of table for more information.
1. Wait until download is finished (can take up to 45 minutes), and then run
the test again.
2. If the test continues to abort and there is no download in progress,
escalate the problem.
2000
ABRT
Response to the test request was not received within the allowable time
period. If Error Type 1538 is present in the Error Log, follow the maintenance
strategy recommended for this error type.
period. If Error Type 1538 is present in the Error Log, follow the maintenance
strategy recommended for this error type.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 136: TEST #210 140AY loop around test (continued)
Error
code
code
Test
result
result
Description/ Recommendation
2 of 3