Communication Manager Maintenance-Object Repair Procedures
940 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Crosstalk testing is performed on both the primary information channel (voice) and the 
secondary information channel (data) associated with each digital station port. If this test fails on 
either channel, the station and the DTDM are taken out-of-service.
Table 321: Test #9 Digital Line NPE Crosstalk Test 
Error 
Code
Test 
Result
Description / Recommendation
1
ABRT
During testing of the primary information channel, system resources were 
not available. Also, the port may have been busy during the test.
1. Enter display port location to determine the station extension 
of the port. Use status station to determine the service state of 
the port. If the port is in use, wait until it is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 
5 times.
2
ABRT
During testing of DTDM, system resources may not have been available. 
Also, the port may have been busy during the test.
1. Check if port is being used. If possible, disconnect by toggling 
disconnect button on DTDM. Retry command after 1 minute.
!
WARNING:
WARNING:
This action will drop the call in progress.
1000
ABRT
System resources required to run this test are not available. The port may 
be busy with a valid call.
1. Enter display port location to determine the station extension 
or attendant number of the port. Use status station or status 
attendant
 to determine the service state of the port. If the port is in 
use, wait until it is idle before testing. Attendants are always in use 
(off-hook) if the handset is plugged in and the port is not busied out.
2. If the port status is idle, retry the command at 1-minute intervals up to 
5 times.
1001
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out of service due 
to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic. 
Retry the command at 1-minute intervals up to 5 times.
 1 of 2