Avaya 03-300430 Manuale Utente
Communication Manager Maintenance-Object Repair Procedures
554 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Expansion Interface Control Channel Test (#316)
This test is nondestructive. If an ATM-EI circuit pack is an active ATM-EI in the PN (amber LED
on long/off short), the Expansion Interface Control Channel test checks to see if the ATM-EI
circuit pack can communicate with other circuit packs in the PN using the PN’s TDM bus.
If the circuit pack is a standby ATM-EI (amber LED off), this test queries the ATM PNC
Expansion Interface circuit pack for information about its type and vintage.
on long/off short), the Expansion Interface Control Channel test checks to see if the ATM-EI
circuit pack can communicate with other circuit packs in the PN using the PN’s TDM bus.
If the circuit pack is a standby ATM-EI (amber LED off), this test queries the ATM PNC
Expansion Interface circuit pack for information about its type and vintage.
0
NO
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board (error 131).
Resolve either of these issues.
2. Check that the board is properly translated and inserted. If so, check
for hyperactivity (error 1538). If hyperactive, use reset board
location.
location.
3. Run the test again. If it fails, the NCE chip on board could be bad.
Replace the board and retest.
Table 175: Test #304 Expansion Interface Lock Query Test (#304) (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 2
Table 176: Expansion Interface Control Channel Test #316
Error
Code
Code
Test
Result
Result
Description / Recommendation
2000
ABRT
Response to the test request was not received within the allowable time
period.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1 of 2