-3-
598-1114-04
Bottom of Sensor
IMPORTANT
Avoid aiming the sensor at:
• Objects  that  change  temperature  rapidly,  such  as
heating  vents  and  air  conditioners.  These  heat
sources could cause false triggering.
• Areas where
pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
... back on.
1 Second OFF
then...
MANUAL MODE
*  If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Manual  mode  only  works  at  night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual  mode  works  only  with  the
ON-TIME  switch  in  the  1,  5,  or  20
position.
ON-TIME
TEST
1  5  20
AUTO
OPERATION
* resets to Auto Mode at dawn.
ON-TIME
D
ual
B
rite
®
TEST
TEST 1 5 20
Off  3  6  Dusk to
   Dawn
Put  ON-TIME  switch
on the sensor bottom
to TEST and the D
ual
-
B
rite
®
switch OFF.
Put ON-TIME switch in the 1, 5,
or 20 minute position.
Mode:
On-Time
Works:
Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 20 Min
x
Manual
To Dawn*
x
Accent
3, 6 Hr, to Dawn
x
MAX 
MIN 
RANGE 
ON-TIME 
DUAL BRITE™ 
TEST  1  5  20 
MINUTES 
OFF  3  6 DUSK TO 
DAWN 
HOUR 
BO
O
S
T
  
Maximum
Maximum Range
Coverage Angle
15 ft.
(4.6 m)
70 ft.  100 ft.
(21 m)  (30.5 m)
Boosted
240°
D
ual
Z
one
D
ual
Z
one
TEST AND ADJUSTMENT
1.
Turn on the circuit breaker and light switch.
NOTE:  Sensor  has  a  1
1
/
2
 minute  warm  up  period
before it will detect motion. When first turned
on, wait 1
1
/
2
minutes.
2.  Turn  the  RANGE  control  to  the  medium  position
(halfway between MIN and MAX), D
ual
B
rite
®
to OFF,
and the ON-TIME control to the TEST position.
Move ON-TIME Switch to 
1, 5, or 20 minutes
Mode Switching Summary
Flip light switch off 
for one second then 
back on*
MANUAL MODE
AUTO
TEST