Heath Zenith BL-1800 Manuale Utente

Pagina di 12
2
598-1321-01
INSTALLATION
For easy installation, select an existing light operated 
by a wall switch for replacement.
For best performance, mount the fixture about 
8 feet (2.4 m) above the ground.
W
ire
 
the
 L
ight
 C
ontroL
For eave mount only:
Wall Mount
Eave Mount
For under eave installation, the sensor head must 
be rotated
 as shown in the next two steps for proper 
operation and to avoid the risk of electrical shock.
  Align the light control cover plate and the junction 
box holes. Secure with the mounting screws.
  If not installed on a weatherproof box or if an adaptor 
plate (not included) was used, 
caulk the wall plate 
and mounting surface with silicone.
M
ount
 
the
 L
ight
 C
ontroL
 Rotate the sensor head towards the clamp screw 
joint.
 Then rotate the sensor head clockwise 180° so the 
controls face down.
Control Switch
Joint Clamp
Adjust the lamp holders by loosening the lock nuts 
but do not rotate the lamp holders more than 180° 
from the factory setting. When screwing in the flood-
lamps, do not overtighten.
Keep  lamps  at 
least  1"  (25  mm) 
from the sensor. 
Avoid  water  damage  and 
electrical shock - keep lamp 
holders below horizontal.
Lock nuts
Black to 
Black
White to 
White
Gasket
Drill  the  holes  needed 
to mount the backplate 
to the junction box.
Remove the existing light fixture.
  Route  the  light  control’s  wires  through  the  large 
gasket hole.
  Connect the junction box wires to the light control 
wires.  Twist  together  and  secure  with  a  wire 
connector.
 WARNING: Turn power off at the fuse or circuit 
breaker.