Bosch ICP-CC404 Manuale Utente

Pagina di 98
ICP-CC404 | Installation Guide | 22.0   Programming Sheets 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 
91
 
Location  
Function 
Options/Notes 
Default/
Programming Entry
The fifth and sixth locations of the output definition provide the time base multiplier. Enter a value between 
01 and 99. 
368 to 397 
Outputs 
(continued) 
One Shot Mode 
When you program the output polarity as one shot, the time base is multiplied by the time base multiplier. 
For example, if the time base = 2 and the multiplier = 05, the output operates for 5 sec. 
Pulsing Mode 
When you program the output polarity as pulsing, the time base becomes the ON time and the multiplier 
becomes the OFF time. The OFF time is the time base, which is multiplied by the multiplier. For example, 
if you want the output to pulse 1 sec ON and 5 sec OFF, you would program time base as 2 and the 
multiplier as 5. 
4  1
398 to 399  
Entry Time 1 
Refer to page 70 
Location 398: increments of 1 sec (0 to 15 sec) 
Location 399: increments of 16 sec (0 to 240 sec) 
8  2
400 to 401  
Entry Time 2 
Refer to page 71 
Location 400: increments of 1 sec (0 to 15 sec) 
Location 401: increments of 16 sec (0 to 240 sec) 
12  3
402 to 403  
Exit Time (AWAY/STAY Modes) 
Refer to page 71 
Location 402: increments of 1 sec (0 to 15 sec) 
Location 403: increments of 16 sec (0 to 240 sec) 
0  0
404 to 405  
Entry Guard Time for STAY Mode 
Refer to page 71 
Location 404: increments of 1 sec (0 to 15 sec) 
Location 405: increments of 16 sec (0 to 240 sec) 
0  0
406 to 407 
Delay Alarm Report Time 
Refer to page 71 
Location 406: increments of 1 sec (0 to 15 sec) 
Location 407: increments of 16 sec (0 to 240 sec) 
0  0
408 to 409 
Sensor Watch Time 
Refer to page 71 
Location 408: increments of days (tens digit) 
Location 409: increments of days (units digit) 
0
410 
Codepad Lockout Time 
Refer to page 71 
0 No 
lockout 
1 to 15  Increments of 10 sec (10 sec to 150 sec) 
5
411 
Siren Run Time 
Refer to page 71 
0 No 
siren 
time 
1 to 15  Increments of 1 min (1 min to 15 min) 
7
412 
Siren Sound Rate 
Refer to page 71 
0 to 15  (slowest to fastest frequency) 
1
413 
Auto Arming Pre-Alert Time 
Refer to page 71 
0 No 
pre-alert 
time 
1 to 15  Increments of 5 min (5 min to 75 min) 
0   0   0   0
414 to 417 
Auto Arming Time 
Refer to page 72 
Location 414: Hour of day (tens digit) 
Location 415: Hour of day (units digit) 
Location 416: Minute of day (tens digit) 
Location 417: Minute of day (units digit) 
 
 
0   0   0   0
418 to 421 
Auto Disarming Time 
Refer to page 72 
Location 418: Hour of day (tens digit) 
Location 419: Hour of day (units digit) 
Location 420: Minute of day (tens digit) 
Location 421: Minute of day (units digit) 
 
 
3
422 
Kiss-Off Wait Time 
Refer to page 72 
0 to 15  Increments of 500 ms (500 ms to 8 sec) 
423 
Reserved 
 
0
1
424 
System Options 1 
Refer to page 73 
1  Bosch smart lockout allowed 
2 Horn 
speaker 
monitor 
4  Strobe indication for radio arm/disarm 
8  Horn speaker beeps for radio arm/disarm