Praesideo 3.5 | Installation and User Instructions | 4 | Amplifiers
en | 144
8.4 Fan 
control
The PRS-1P500, PRS-2P250 and PRS-4P125 amplifiers, 
from HW version 06/00 onwards, have a fan 
monitoring circuit that detects the actual fan rotation. 
This detection is needed for compliancy to the standards 
UL864 and UL1711, for use in the USA. Additionally 
the internal fans need to run at full speed for 
compliancy to these standards. A jumper on the main 
PCB selects between two positions:
Normal (factory default) - The fans are temperature 
controlled, normally running at low speed and 
switching to high speed in case the temperature 
exceeds a certain level. Fan monitoring is not 
activated.
Full speed - The fans run at full speed continuously. 
Fan monitoring is activated. Do not enable Switch 
amplifiers to standby (see section 44.4) for this 
selection, because in standby the fans are stopped 
and a fault would be generated.
The jumper is indicated on the PCB as X18; connection 
1-2 selects Normal, connection 2-3 selects Full speed. 
See figure 8.15.
figure 8.15: Jumper X18 provides fan control for PRS-1P500, PRS-2P250 and PRS-4P125
PRS-1P500, PRS-2P250 and PRS-4P125
1
2
3
X18