31.3 Dust 
caps
Protect the POF parts of the system cables and 
connectors that are not in use with dust caps. Dust caps 
also block the red light from the fiber optic interface, 
which might be visible and disturbing.
31.4 Maximum 
distance
Due to light loss, the maximum length of POF cabling 
(and therefore also system bus cables) between two 
pieces of equipment is 50 m. If the distance between two 
units is more than 50 m, PRS-FIN(NA) or PRS-FINS 
Fiber Interfaces and glass optical fibers (GOF) must be 
used (see figure 31.4).
If GOF cables are used, make sure that they:
are multimode GOF cables (single mode GOF 
cables are supported by the PRS-FINS);
have a maximum attenuation of 2 dB/km;
are suitable for light with a wavelength of 1300 nm;
are terminated with standard SC connectors.
Note
During both installation and operation, the 
temperature of the POF cabling may not exceed 
65 °C. Higher temperatures can damage the 
fibers.
Note
The POF part of the system bus connectors on 
the Praesideo equipment are F05 and F07 
compliant. This means that if only data has to be 
transported, industry-standard F05 or F07 
connectors can be used. If only POF cabling is 
used between two units, no power is 
transported between these pieces of 
equipment.
figure 31.3: Dust cap
figure 31.4: Using fiber interfaces
Note
It is also possible to increase the distance 
between units above 50 m by inserting 
PRS-NSP Network Splitters every 50 m or less. 
Although no tap-off may be required, the 
network signal is regenerated in the network 
splitter to cover another 50 m.