Chauvet color ado1ip Manuale Utente

Pagina di 28
Operation 
 
 
-10- 
 
COLORado™ 1 IP User Manual Rev. 01c 
Continued from previous page 
 
DMX Control With ID 
Addressing 
 
In this mode, the fixtures with the same DMX starting address will respond to the DMX 
controller based on the fixture’s individual ID address setting. If the user selects ID 
address “0”, all the fixtures with the same DMX address will respond in unison. 
Otherwise, each fixture will follow the control for its particular ID address.  
1)  Repeat steps 12, and 3 from DMX Control Without ID Addressing
2)  Activate ID Addressing in each fixture: 
a)  Go to SET > ID
b)  Select ON
3)   Select an ID address for each fixture: 
a)   Go to ID
b)   Select an ID (01~66
   
 
Static Color 
 
The Static Color mode allows for permanent RGBW color mixing without a DMX 
controller. 
1)  Go to STAT
2)  Select the desired color (RedGreenBlue, or White). 
3)  Select the desired color value (0~255). 
4)  Repeat for the other colors. 
5)  Select Strob
6)  Select the desired frequency (0~20). 
   
 
Auto Programs 
 
Auto programs allow for dynamic RGBW color mixing without a DMX controller. 
1)  Go to AUTO
2)  Select the desired auto program (AT. 01~10 or PR. 01~10). 
 
 
 
 
 
You cannot edit auto programs AT. 01~10. However you can edit PR. 01~10 (see 
Edit Customs
). 
   
 
Edit Customs 
 
This setting allows for the programming of up to 30 scenes for each of the 10 
customizable programs, including colors and effects. 
1)  Go to EDIT
2)  Select the desired auto program (PR. 01~10). 
3)  Select the desired scene (SC. 01~30). 
4)  Select the desired color or effect (Red,  Green,  Blue,  White,  Strobe,  Time,  or 
Fade). 
5)  Select the desired value for the color or  effect  (000~255  for colors and timers, or 
00~20 for Strobe). 
6)  Repeat for the other colors or effects. 
7)  Repeat for the other scenes. 
   
 
Master/Slave 
 
The Master/Slave mode allows a group of COLORado™ 1 IP  fixtures (the slaves) to 
execute simultaneously the same program, whether auto or custom, that another 
COLORado™ 1 IP fixture (the master) is executing, without a DMX controller. 
1)  Set the Master Unit: 
a)  Set the running mode to DMX  as explained in “DMX  Control Without ID 
Addressing”. 
b)  Select an auto program as explained in “Auto Programs”. 
2)  Set the slave units: 
a)  Go to RUN
b)  Select SLAV
 
 
 
 
 
•  The fixture that runs an auto program automatically becomes the Master.  
•  Do not connect a DMX controller to the master or slave fixtures. 
 
 
 
 
 
Continues on the next page