General Troubleshooting 
 
 
 
S
YMPTOM
 
P
OSSIBLE 
C
AUSE
(
S
P
OSSIBLE 
A
CTION
(
S
Breaker/Fuse 
keeps blowing 
·  Excessive circuit load 
·  Check total load placed on the electrical 
circuit 
·  Short circuit along the power 
wires 
·  Check for a short in the electrical wiring 
(internal and/or external) 
Device does not 
power up 
·  No power 
·  Check for power on Mains 
·  Loose power cord 
·  Check power cord 
Fixture is not 
responding to DMX 
·  Wrong DMX addressing 
·  Check Control Panel and unit 
addressing  
·  Damaged DMX cables 
·  Check DMX cables 
·  Wrong polarity settings on the 
controller 
·  Check polarity switch settings on the 
controller 
·  Loose DMX cables 
·  Check cable connections 
·  Faulty DMX interface 
·  Replace DMX input 
·  Faulty Main PCB 
·  Replace Main PCB 
Loss of signal 
·  Non DMX cables 
·  Use only DMX compatible cables 
·  Bouncing signals 
·  Install terminator as suggested 
·  Long cable / low level signal 
·  Install amplifier right after fixture with 
strong signal. 
·  Too many fixtures 
·  Install an optically coupled DMX splitter 
after unit #32 
·  Interference from AC wires 
·  Keep DMX cables separated from power 
cables or black lights 
 
 
 
 
If you still have a problem after trying the above solutions, please contact CHAUVET® Technical 