TRoUBlesHooTING
Continued 
 WARNING: If you smell gas
•  Shut off gas supply.
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your 
building.
•  Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning sup-
plies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., 
create fumes. These fumes may mix with combustion air and create odors. These odors will 
disappear over time.
POSSIBLE CAUSE
1. Battery  is  not  installed. 
Battery power is low
2. Bad module
1. Metal  expanding  while 
heating  or  contracting 
while cooling
1. Heater burning vapors from 
paint,  hair  spray,  glues, 
cleaners,  chemicals,  new 
carpet, etc. (See IMPOR-
TANT statement above)
2. Low fuel supply (propane/
LP only)
3. Gas  leak.  See  Warning 
statement at top of page
1. Not  enough  fresh  air  is 
available
2. Low line pressure
3. ODS/pilot  is  partially 
clogged
4. Thermostat  on  remote  is 
satisfied
1. Gas  leak.  See  Warning 
statement at top of page
2. Control valve or gas control 
defective
1. Foreign  matter  between 
control valve and burner
2. Gas  leak.  See  Warning 
statement at top of page
REMEDY
1. Replace  batteries  in  re-
ceiver and remote control
2. Replace module
1. This  is  normal  with  most 
heaters.  If  noise  is  exces-
sive, contact qualified ser-
vice person
1. Open  window  to  venti-
late room. Stop using odor 
causing  products  while 
heater is running
2. Refill supply tank (propane/
LP only)
3. Locate and correct all leaks 
(see  Checking  Gas  Con-
nections, page 13)
1. Open  window  and/or  door 
for ventilation
2. Contact  local  natural  or 
propane/LP gas company
3. Clean  ODS/pilot  (see 
Cleaning and Maintenance
page 20)
4. Adjust temperature
1. Locate and correct all leaks 
(see  Checking  Gas  Con-
nections, page 13)
2. Replace  control  valve  or 
gas control
1. Take apart gas tubing and 
remove foreign matter
2. Locate and correct all leaks 
(see  Checking  Gas  Con-
nections, page 13)
OBSERVED PROBLEM
Remote does not function
Heater  produces  a  clicking/
ticking noise just after burner 
is lit or shut off
Heater  produces  unwanted 
odors
Heater shuts off in use (ODS 
operates)
Gas odor even when control 
knob is in OFF position
Gas odor during combustion