FINISH MOUNTING AND PLUMBING 
THE HUMIDIFIER
1. Mount the humidifier as instructed in the Select 
Location and Mount section.
2. Route the tubing to the humidifier float valve.
IMPORTANT
Keep the tubing away from sharp edges.
3. Connect the remaining end of the tubing to the 
humidifier float valve.
4. Open the saddle valve so the water flows slowly 
into the water pan.
5. Check the compression fittings at the saddle valve 
and the float valve. Tighten the fitting slightly to stop 
any leakage.
6. Connect the overflow provision of the humidifier to a 
suitable waste drain.
NOTE: 3/8 in. (9.525 mm) I.D. tubing can be easily 
attached to the overflow fitting.
7. Support the drain line at several locations to pre-
vent kinks. Be sure to provide support near any 
heat source.
8. Use a male 1-1/2 in. NPT fitting (not supplied) to 
connect the humidifier overflow provision.
INSTALL THE AUTOMATIC 
FLUSHING TIMER
Refer to the “Installation Instructions for the 
Programmable Humidifier Automatic Flushing Timer” for 
complete instruction.
INSTALL THE AUTOMATIC 
HUMIDISTAT CONTROL
For additional humidistat installation instruction, refer to 
the manual “Wiring Instructions for High-Capacity Steam 
Humidifiers.”
WARNING
Electrocution Hazard. Disconnect electrical 
power to the furnace before beginning 
installation.
Sharp edges. Use caution when cutting plenum 
openings and handling ductwork
CAUTION
Do not mount the compensating humidistat on 
the supply duct or plenum. The unit will not 
withstand supply temperatures.
Do not set the humidity so high that condensation 
forms on windows or walls.
SELECT LOCATION AND MOUNT
1. Check contents of the humidistat carton. Compo-
nents include:
Automatic humidistat
Outdoor temperature sensor
Sensor shield
Manual mode faceplate
Mounting bracket
2. Disassemble the humidistat. Pull knob off, then 
remove the cover by inserting a screwdriver in the 
slot on the right side of the humidistat.
3. Mount the humidistat on the COLD AIR RETURN. 
Select a mounting location at least 6 inches 
upstream from the fresh air intake ductwork, if appli-
cable.
4. Select an exterior location to mount the Outdoor 
Temperature Sensor. Location must meet the fol-
lowing requirements. Incorrect indoor humidity lev-
els will result if these requirements are not met.
Mount on North, Northeast or Northwest side of 
house.
Mount at least 3 feet from all exhaust vents.
Mount above expected snow line.
NOTE: For manual operation, do not install the outdoor 
sensor wire.
5. Locate an existing Indoor/Outdoor access hole.
Make sure there are no active high-voltage 
wires in the hole.
As an alternative, the sensor can be mounted in 
the center of a 6-inch fresh air intake duct (must 
be no farther than 30 inches from the outside 
wall).
NOTE: If neither configuration is possible, the compen-
sating humidistat can be installed to operate 
manually. See Installing the Humidistat to Oper-
ate Manually,
 below.
6. Route the sensor wire to the selected location. Run 
wire between the compensating humidistat and the 
outdoor sensor lead. If the sensor is outdoors, snap 
the probe end of the sensor into the sensor shield 
and attach it to an exterior wall. The probe must be 
completely covered by the shield.
NOTE: Outdoor temperature sensor wire must not 
exceed 30 feet in length.
CAUTION
Do not run outdoor temperature sensor wire 
alongside wires carrying high voltage (120 
VAC or higher). Do not run the sensor wire 
through conduit.
7. Attach the Sensor Wire to the humidistat. Strip the 
connecting wire 1/4 inch and attach the two internal 
wires to the terminals labeled “Outdoor Tempera-
ture Sensor” on the humidistat.
8. Select a power source. The voltage to the humidis-
tat must be between 22-30 VAC.
NOTE: The compensating humidistat will operate prop-
erly only with a continuous power source. A min-
imum 10 volt amperes is required.
9. Connect the humidistat to the humidifier. Strip the 
wires used for all the humidistat terminal connec-
tions 1/4 inch.
10. Set the humidistat. Consult the compensating humi-
distat homeowner's manual for proper humidity set-