Thermo Products HA1042 Dépliant

Pagina di 2
Application:
    
Forced warm-air furnaces
Unit Size: 
    
15" wide x 11½" high x 9" deep     
Plenum Opening:
     
10¼" wide x 9½" high
Bypass Duct: 
    
6" diameter (collar supplied)
Water Supply: 
    
Use ¼" copper (saddle valve supplied)
Electrical: 
    
Model HA1042 Drain Type with Humidistat - 24 V. 60 Hz.
Drain Connections:    
5/8" dia. (15' vinyl hose supplied)
Controls: 
    
Manual air shutter Humidistat with HA1042
Specifications
Type of
Construction
Size of House (sq. ft.)*
500
1000
1500
2000
2500
3000
Tight
Average
Loose
2.1
3.3
4.6
4.2
6.5
9.2
6.4
9.8
13.8
8.5
13.1
18.4
10.6
16.3
23.0
12.7
19.6
27.6
Evaporative Capacity Output
Temp°F
80°
100°
120°
140°*
160°
GPD
8.0
12.2
16.4
19.2
23.2
*Industry Standard rating conditions. 140° hot water supplied to 
the humidifier in heat pump applications will increase capacity by 
4.3 gallons per day.
HUMIDITY REQUIREMENTS IN GALLONS PER 
DAY BASED ON HOUSE SIZE AND TYPE OF 
CONSTRUCTION (FROM ARI GUIDELINE F)
*Based on 8 ft. ceiling height.
Tight House
With insulated walls and ceilings, vapor barriers, weather 
stripping on doors and windows, and snug doors, windows 
and fireplace damper (½ air change per hour)
Average House
Insulated walls and ceilings with vapor barriers, but loose 
storm doors, windows and fireplace damper (1 air change 
per hour)
Loose House
Without insulation, storm doors, storm windows, weather 
stripping or vapor barriers (2 air changes per hour)
Illustrations and photographs in this brochure are only representative.
Due to ongoing engineering upgrades, some variations may occur.
Form No. PL81410061006-2/06-3Ms
Printed in the U.S.A.
© 2006 Thermo Products, LLC - North Judson, IN
Phone: 574-896-2133
www.thermopride.com