Johnson Controls 4000 Dépliant

Pagina di 2
Humidifier specifications
Humidifier 
Type
sizing  
sq. Ft. Area  
(air changes/hr)
A.  Unit size 
(inches)
B.   Plenum 
Opening 
(inches)
Bypass 
Connection 
size
Water Feed 
rate
Electrical 
Data
UL 
Approved
Components 
Included
8000 series 
Canister 
steam 
Humidifier
120V operation:
750 loose (2), 1,500 average
(1), 3,000 tight (1/2)
208V operation:
1,350 loose (2), 2,650 average
(1), 5,350 tight (1/2)
240V operation:
1,500 loose (2), 3,050 average
(1), 6,100 tight (1/2)
A.  
10-1/8 W x
20-7/8 H x
7-1/8 D
B.   N/A – Unit
can be remote
mounted.
N/A –
Dispersion
tube mounts
through
1-1/4” hole
in supply or
return duct.
N/A – Total
water usage
is output plus
approximately
20% for drain
cycles.
120V-60Hz:
11.5 AMP,
1.4 kW
208V-60Hz:
11.5 AMP,
2.4 kW
240V-60Hz:
11.5 AMP,
2.8 kW
UL
Approval
certified
by ETL
Manual Humidistat,
Dispersion Tube,
Steam Hose, Drain
Hose, Hose Clamps,
Blower Activation
Relay, Installation/
Operation &
Maintenance Manual,
Owners Manual
7000 series 
Power 
Humidifier
1,050 loose house (2)
2,100 average house (1)
4,200 tight house (1/2)
A.  
15-29/32 W x
18 H x
10-11/32 D
B.   14-3/4 W x
14-5/16 H
N/A
6 gph
120V-60Hz
0.8 AMP
Yes
Manual Humidistat
Saddle Valve,
Installation Template,
Owner’s Manual
6000 series 
Bypass 
Humidifiers
1,000 loose house (2)
2,000 average house (1)
4,000 tight house (1/2)
A.   15-3/8 W x
15-3/4 H x
10-1/4 D
 
 6” dia. round 
opening 
for bypass 
connection
B.   10 W x
12-3/4 H
6”
3 gph
24V-60Hz
0.5 AMP
Yes
Manual Humidistat
Saddle Valve,
Installation Template,
Owner’s Manual,
24-volt Transformer
4000 series 
Water saver 
Bypass 
Humidifiers
1,000 loose house (2)
2,000 average house (1)
4,000 tight house (1/2)
A.   15-3/8 W x
15-3/4 H x
10-1/4 D
 
 6” dia. round 
opening 
for bypass 
connection
B.   10 W x
12-3/4 H
6”
3 gph
24V-60Hz
0.5 AMP
No
Manual Humidistat
Saddle Valve,
Installation Template,
Owner’s Manual,
24-volt Transformer
5000 series 
Bypass 
Humidifiers
750 loose house (2)
1,500 average house (1)
3,000 tight house (1/2)
A.   15-5/8 W x
13 H x
10-1/4 D
 
 6” dia. round 
opening 
for bypass 
connection
B.   9-1/2 W x
9-1/2 H
6”
3 gph
24V-60Hz
0.5 AMP
Yes
Manual Humidistat
Saddle Valve,
Installation Template,
Owner’s Manual,
24-volt Transformer
series 8000, 7000, 6000, 5000, 4000 humidifier performance based on:
a.  20°F and 70% R.H. Outside Air
b.  0°F and 35% R.H. Room Air
c.  Internal Moisture Gain of 1 lb/hr 
d.  70% Blower Operation
e.  8 Ft. Ceiling Height
Johnson Controls 
Unitary Products 
5005 York Drive, Norman, OK 73069
665513-UTG-B-1211
Johnson Controls, Unitary Products reserves the
right to change specifications without notice.