Wayne-Dalton 2411 Manuale Utente

Pagina di 16
PG. 4
STEP 10: Attaching the Back Hanger Angles: Apply another locking pliers above the No. 2 or No. 3 roller
and then remove the locking pliers from the top roller. With assistance push downward on the door and
remove all locking pliers. Carefully raise door until one and a half panels are in the horizontal track, lock
door into position using locking pliers.
Space the horizontal tracks 3/4” from section edge and level (or running upward).  Using 1-5/8” x 2-3/8”
x 12 GA. Min. Angle, secure each horizontal track to the building as shown in Fig.  Using 3/8” bolts and
nuts . Lateral brace all drop angles once proper spacing is determined.
Doors over 11 ft. high and over 14 ft. wide must have (1) intermediate drop hanger as shown above right
side.
Doors between 16’ and 18’ high must have (2) center hanger assemblies as shown above left side.
Doors over 18’ high must have center hangers placed at 6’ center max.
STEP 11: Checking the Counterbalance: Release the locking pliers from vertical track and check the door’s
counterbalance. Adjust springs if necessary.
STEP 12: Vertical Track and Top Bracket Adjustments: Vertical tracks can now receive final adjustments.
Open and close the door a few times, checking and adjusting side clearance (if necessary). Tighten jamb
fasteners (lags, teks, and anchors) to permanently secure verticals. Adjust door in or out from jamb by
loosening the track to obtain proper seal. Permanently tighten all track bolts. Adjust top bracket roller
carrier so that the top section is sealed against header.
STEP 13: Lubrication: Lubricate springs, rollers, and bearings with oil.
 
DO NOT GREASE THE INSIDE OF THE TRACK.
Intermediate hangers for all
doors over 11’ high and over
14’ wide. Positioned half way
between jamb and rear hanger.
Lateral brace all hanger
angles.
Use a 3/8” X 3/4”
truss bolt for
roller clearance.
Apply locking pliers to
secure while attaching
hangers.
Use 12 GA. Minimum
angle (1-5/8” X 2-3/8”)
Doors 16’ to 18’ use 2
intermediate hangers.
Over 18’ use hangers at
6’ max. centers
3/8” dia. Bolt should
protrude into track
to serve as a roller
stop.
PG. 13
2” TRACK 1/4” GRADUATION
8 SECTIONS HIGH OR LESS
FIG.B
FIG.E
FIG.D
FIG.C
STEP 3.  Locate the left and right hand bottom brackets, secure the counterbalance cable using clevis pin,
washer and cotter key shown in fig. B
               Secure bottom bracket to section using 1/4” self-drilling and tapping screws shown in fig. C
( for doors over 14’2” wide use double wide bottom brackets as shown in figure G)  ( For doors
using Broken Cable Safety Device Refer to Fig. J and the auxiliary instructions.)
FIG.A
#1 HINGE
#2 HINGE
#3 HINGE
Step Plate (provided on
insulated doors)
1/4”-20 X 7/8”  TEK
Screws (2)
Lift Handle
1/4”-20 Whiz Nuts (2)
Spacer (2)
1/4”-20 X 2-1/2” Hex
Head Bolt (2)
Lift Handle
Roller spacer (1/2” long)
required on BB-6 type bottom
brackets. Secure bracket with
(5) screws
NOTE:  2” TRACK HINGE SCHEDULE FOR
DOORS LESS THAN OR EQUAL TO 16’-1”
HIGH.