Plenum Temperature Sensor
The plenum temperature sensor is
the small grey PVC junction box at-
tached by a cord to the fan/heater
control box on the master fan/heater
unit.
1. On either side of the fan/heater,
drill one 3/4” hole even with the
fan/heater unit in a valley on the
bin sidewall.
2. Insert the probe through the
3/4” hole.
3. Position the housing so the cord
exits the housing horizontally,
and the tabs fall on the sidewall
peaks.
4. Use two self drilling screws to
mount the housing to the bin
sidewall.
5. Caulk between the housing and
the sidewall to seal.
     Important!
If the Top Dry is a two fan unit,
do not mount the plenum tem-
perature sensor between the two
fan/heater units.
Plenum temperature sensor on the bin sidewall.
INSTALLATION