Fan and Heater Mounting
1. Inspect the fan platform for proper installation
per instructions in the Top Dry erection manual.
2. Raise the Top Dry fan and heater units to the
plat form. Use the table to the right to determine
the height of the platform from the base of the
TopDry unit.
3. Mount the Top Dry fan and heater units to the
bin entrance sheets. Fan legs should set on the
plat form.
Top Dry Bin Eave Height
Number
of Rings
5
6
7
8
9
10
11
Eave
Height
18’-5”
22’-1”
25’-9”
29’-5”
33’-1”
36’-9”
40’-5”
Autoflow Control Box Mounting
1. The Autoflow Control Box should be
mounted at eye-level.  Make sure to mount
the Autoflow  control box so that  the fan
and heater unit(s) are in view.
Autoflow Control box mounted on bin.
2. Keep in mind that wire will be used to inter
connect the Autoflow  control Box  with the
INSTALLATION
fan and heater  unit(s), Fill System Control
Box, Actuator and all rotary switches.
3. Use the hole pattern in Figure 1 to drill holes
for mounting the Autoflow Control Box.
Save for Control box mounted on  Bin picture