Measuring the
Door Opening
H
W
The Viewpoint Screen requires a minimum
Mounting Surface of 1 3/4" (45 mm). This
mounting surface must be flat and flush, and at
a right angle (90º) to the door.
Mounting Surface of 1 3/4" (45 mm). This
mounting surface must be flat and flush, and at
a right angle (90º) to the door.
For the Width - Measure the width of the
opening between the right and left surfaces of
the door frame, record this dimension in the box
below labeled “W”.
opening between the right and left surfaces of
the door frame, record this dimension in the box
below labeled “W”.
For the Height – Measure the height of the
opening between the underside of the top of
the door frame (or filler strip), and the top of
the door sill at a point 1 3/4" (45 mm) from the
front surface of the frame. Record this
dimension in the box below labeled “H”.
opening between the underside of the top of
the door frame (or filler strip), and the top of
the door sill at a point 1 3/4" (45 mm) from the
front surface of the frame. Record this
dimension in the box below labeled “H”.
NOTE: If the height of the door opening is
greater than the maximum height requirement,
it is still possible to install the Viewpoint
Screen. Simply attach a filler strip under the
top of door frame to reduce the height of the
opening to at least 80 9/16" (2,047 mm). Be
sure to attach the filler strip before taking the
height measurement.
greater than the maximum height requirement,
it is still possible to install the Viewpoint
Screen. Simply attach a filler strip under the
top of door frame to reduce the height of the
opening to at least 80 9/16" (2,047 mm). Be
sure to attach the filler strip before taking the
height measurement.
=
=
6
W
H
A
1 3/4”
(45 mm)
mounting
surface
(45 mm)
mounting
surface
Door Sill