Aiphone C-123LW Manuale Utente

Pagina di 4
1
E
E
-
1
L
L
+
-
RY-AC
BELL
SKK-620B
IMPORTANT:  Connect wires 
before applying power.
C-123LW Supplement
Pg. 3
WIRING DIAGRAM: LEM-1DL System with External Signaling using RY-AC Relay
+
MODIFICATION INSTRUCTIONS: 
C-ML/A with Door Release contact Modifi ed to Normally Closed (for Magnetic Lock)
Normally Open Dry 
Contact to door 
strike and power
Component Module*
If a DAK-2S is not available, install components as shown below.
Capacitor: 25V, 15-33ufd Non-polarized
Diode: 1N4148
Output of RY-AC (Yellow 
wires) provide a momentary 
dry contact closure while 
the call button on the door 
station is being pressed.
12V DC power 
supply
NOTE: Negative of 
power supplies must be 
tied together.
C-ML/A
Component 
Module*
C-D
White
Red
Black
Power source
for bell
To 1 of C-D and 
WHITE wire of RY-AC
To 1 of C-ML/A
Magnetic locks require Normally 
Closed contacts, keeping power 
applied to the magnet to keep the door 
locked, and breaking power to release 
the door.  These instructions explain 
how to change the contact in the 
C-ML/A to Normally Closed.
1.  Remove back chassis of C-ML/A 
     and move the PC-754 board aside.  
     Black door release switch will be 
     visible.
2.  On the switch, move* the wire from 
     the NO contact (middle position) to 
     the NC contact (top position).  
     *Desoldering and resoldering is 
     required.
3.  This modifi cation will change the 
     door release button’s function to 
     Normally Closed, to be used with 
     magnetic lock device.
4.  Switch contact rating is 1A at 50V 
     AC.
+
-
60H-2
A
8
THA1
547
Door release
switch
COM
NO
NC
C-ML/A Rear View with PC board removed.