7. Place top left log (BE9 or BF11) onto locator notches.  
Ensure log is secure.
8. Place top right log (BE10 or BF12) onto locator 
notches.  Ensure log is secure.
Ember Material Placement
Separate the ember material into small pieces and 
place onto the burner in front of the front logs.  Do NOT 
pack down, leave in fluffy, loose condition for most re-
alistic ember effects.  Do not install more embers on 
the burner than come with the unit.
Application of excess loose material may adversely 
affect performance of theheater.
Replacement loose embers must be purchased 
through authorized Majestic Fireplaces dealers.
WARNING: All previously applied loose 
material must be removed prior to reappli-
cation.
Lava Rock
The lava rock provided with this fireplace must be 
placed on the firebox bottom on either side of the 
burner assembly. Do not place lava rock in combustion 
pan.
Under no circumstances should this lava 
rock be placed on any part of the burner 
assembly.
LG131
UVC/UVS36 LOGS
9/8/00   djt
BE10
BE8
BE7
BE6
BE9
LG131
Fig. 14 UVC/UVS36 log placement.
LG132
UVC/UVS43
Log placement
9/8/00   djt
BF11
BF8
BF9
BF10
BF12
LG132
Fig. 15  UVC/UVS43 log placement.
Flame Adjustment
For fireplaces equipped with HI/LO valves, flame ad-
justment is accomplished by rotating the HI/LO adjust-
ment knob located near the center of the gas control. 
(Fig. 16)
LO
HI
Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
HV102
Honeywell hi/lo knob
4/5/99   djt
Fig. 16  Flame adjustment knob for Honeywell Valve.
Flame Characteristics
It is important to periodically perform a visual check 
of the pilot and burner flames. Compare them to the 
Figures 17 or 18. If the flame patterns appear abnor-
mal, contact a qualified service provider for service and 
adjustment.
Fig. 18   Approximate flame heights for each model.
UVC36/UVS43
UVC43/UVS43
LG131
UVC/UVS36 LOGS
9/8/00   djt
LG134
UVC/UVS43
Log placement flames
9/8/00   djt
LG133
LG134
IF449 
NOVA SIT PILOT
UVC
2/14/97
FP449
Fig. 17  Correct pilot flame pattern.
First Firing
Upon completing the gas line connection, a small 
amount of air will be in the lines. When first lighting unit 
with pilot light, it will take a few minutes to purge them-
selves of this air. Once the purging is complete, the 
pilot and burner will light and operate as indicated in the 
instruction manual. Subsequent lightings of the heater 
will not require such purging.
When lit for the first time, the appliance will emit a slight 
odor for awhile. This is due to paint and lubricants used 
in the manufacturing process. After each lighting, vapor 
may condense and fog the glass; this moisture disap-
pears within a few minutes of burning.