CFM UVS36 Manuale Utente

Pagina di 20
17
Majestic Fireplaces
® 
UVC / UVS Vent-Free Heaters
20000135
Optional Accessories
Fan Kit
FK24 Fan Assembly
Fan specifications: 120 volt, 60 Hz, .75 Amps
This fan does not need regular maintenance, however 
periodic cleaning is required. Check the area under the 
control door and in front of the fan and wipe or vacuum 
at least once a month during the operating season. 
Should this fan require servicing, the power supply 
must  be disconnected.
The FK-24 comes with the electrical cord attached.
1.  Slide fan assembly from the left side into the fire-
place opening, line up mounting holes with screw 
studs on back of fireplace and fasten with #10-24 
hex nuts.
2.  Install thermal sensor on bottom of firebox using 
#10-24 hex nuts.
3.  (Option A) - Place electronic fan speed control box 
on bottom of fireplace base, lining up mounting holes 
with screw studs. Fasten fan speed control box with 
#10-24 hex nuts.
  (Option B) - The speed control can be installed in 
an electrical box at normal wall switch height for 
convenient access.
4.  The power supply may be connected in 2 ways: 
Method A - route the 6' (1.8m) lead fitted to the unit 
to a conveniently located wall socket.
  Method B - If the EB-1 receptacle box (Pt. 
#ZA1200) was correctly connected when the unit 
was installed, the fan lead can be directly plugged 
into the EB-1 plug socket. 
5.  Whether wiring directly to the fan junction box, (Op-
tion A) or into the EB-1 (Option B), first ensure cable 
is secured using box connector.
The fireplace, when installed must be electrically 
connected and grounded in accordance with local 
codes or, in the absence of local codes, with the 
current CSA C22.1 Canadian Electrical Code or for 
US installations, follow local codes and the National 
Electrical Code, ANSI/NFPA No. 70.
Hard (Direct) Wire Hook-Up
First connect the ground wire to the ground stud located 
on the base  of either box. Black wire from supply 
should connect to the variable speed switch. Alternate 
speed switch wire connects to temperature sensor. Al-
ternate lead from sensor connects to fan. Alternate fan 
lead connects back to the white supply wire. (Fig. 20)
Any electrical rewiring of this fan must be 
completed by a qualified electrician.
Turn off all power before hook-up.
FP394
WIRING DIAGRAM
11/20/96
Fan
Temperature 
Sensor
Speed 
Control
Black
White
Ground
FP394
Fig. 20  FK-24 wiring.
Remote Controls
Optional remote control units are available to control 
different functions of the appliance.
 
Model 
Function(s) Controlled
 
MRC1 
ON/OFF
 
MRC2 
ON/OFF and Temperature
 
MRC3 
ON/OFF and Temperature control  
 
 
with a digital and a programmable  
 
 
24 hour clock
 
IMT 
Wall mounted thermostat control
Ceramic Refractory Panels
Ceramic refractory panels are available to line the fire-
box area. 
 
Unit 
Kit Model
 
UVC36 
UV36CR
 
UVS36 
UV36CR
 
UVC43 
UV43CR
 
UVS43 
UV43CR
Take care when handling the refractory panels as they 
are fragile until held in place and supported.
Arched Door Front
The arched door front kit is designed to visually en-
hance the appearance of the UVC36 fireplace only. 
 
DV36ADKP 
Polished Brass
 
DV36ADKA 
Antique Brass