Amana GUD-X Manuale Utente

Pagina di 4
Amana
Fayetteville, TN 37334
A higher standard of comfort
Heating 
¡
 Air Conditioning
®
11134620
GUD-X
High Efficiency
Gas Fired
Warm Air Furnace
Due to continuous engineering de-
sign and development, the above
information is subject to change with-
out notice.
Affix this Specification Sheet, Installation Instructions and
User Information manual adjacent to the unit.
Specification Sheet
1
 Minimum Circuit Ampacity = (Circulating Blower Amps x 1.25) +  I.D. Blower Amps
2
 Maximum Overcurrent Protection refers to maximum recommended fuse or circuit breaker size.
3
 As shipped for installations below 4,000 feet.
Dimensions
WARNING
To avoid death, personal injury or
property damage due to fire, do not
exceed maximum recommended
fuse or circuit breaker size.
All dimensions are in inches.
 
 
Temp.
Blower
Pressure 
Model Number
Input
(BTUH)
Output
(BTUH)
AFUE
Rise 
Range, °F
Number 
of 
Burners
Minimum 
Circuit 
Ampacity
1
Maximum 
Overcurrent 
Protection
2
D" x W"
HP
Speeds
AC Tons @ 
.5 ESP
Switch Setting 
(Inches W.C.)
3
Shipping 
Weight
(lbs)
GUD045X30B
45,000
43,000
95.6
25-55
2
11.3
15
10X8
1/3
3
2.0-3.0
-1.38
158
GUD070X30B
70,000
65,700
93.8
35-65
3
10.3
15
10X8
1/3
4
2.0-3.0
-1.38
194
GUD070X40B
70,000
65,700
93.8
35-65
3
14.1
15
10X10
3/4
4
3.0-4.0
-1.38
194
GUD090X35B
90,000
84,300
93.7
45-75
4
10.1
15
10X8
1/2
4
2.0-3.5
-1.57
216
GUD090X50B
90,000
85,100
94.6
35-65
4
15.1
20
10X10
3/4
4
3.5-5.0
-1.57
216
GUD115X50B
115,000
107,600
93.6
35-65
5
15.1
20
10X10
3/4
4
3.5-5.0
-1.38
231
Size
A
B
C
D
E
45
16-1/2
15
7
10-1/2
2-5/8
70
20-1/2
19
11
14-1/2
2-5/8
90
24-1/2
23
10-1/2
18-1/2
4-5/8
115
24-1/2
23
12-1/2
18-1/2
2-5/8
Top View
Gas Supply Hole
Electrical Hole
Line Voltage
1-3/4
2
Combustion
Air Inlet
Flue Outlet
4-1/4
4-3/8
2-1/2
C
E
1-1/8
Front View
Left Side View
28-1/8
28
20-1/8
23
28-3/4
38-3/4
40
48
23
Bottom KO
14
A
B
16-1/2
38-1/4
3/4
2-3/8
3/4
1-5/8
1-5/8
3/4
Bottom KO
D
Side KO
Electrical 
Hole-Low
Voltage
Gas
Supply
Hole
Electrical 
Hole-Line
Voltage
Supply
1-5/8
5-7/8
6-5/8
Condensate Drain
(Left or Right Side)
38-3/4
Right Side View
4-3/4
6-5/8
Supply
Gas
Supply
Hole
Electrical 
Hole-Low
Voltage
January 1998