Empire Products GWT-35-2 Manuale Utente

Pagina di 20
12425-7-0406
Page 17
Index 
Part 
No. 
Number 
Description
  1 
GW-130 
Remote Bulb Control Kit
  2 
R-1224 
Remote Bulb Control
  3 
R-2499 
Wire Assembly
  4 
R-1162 
Control Knob
  5 
R-1720 
Plastic Clip (3 Required)
  6 
R-1223 
Instructions
  7 
R-1578 
No. 6-32 x 1/4" (6mm) Screw (2 Required)
Caution:    Remote bulb wire routing is important.  Wires should be 
in proper location to avoid damage from being overheated.  
Incorrect routing of remote bulb control wires may result 
in damage to wires and incorrect  operation  of remote bulb 
control.  Follow these instructions and refer to the drawing 
for proper wire routing.
  7.  If remote bulb control is located on the right side of the outer cas-
ing, carefully bend or loop capillary wire around control.  This will 
enable the sensing bulb to be positioned at the bottom of the unit.
  8.  Secure sensing bulb on the inside, at the bottom, of the outer casing 
with (2) plastics clips.
  9.  Feed the wire assembly down along the inside of the outer casing.
 10.  Use third plastic clip to secure wire assembly and capillary wire to 
the casing.  (Approximately 24" (610mm) from bottom of unit.)
 11.  Attach control knob to remote bulb control.
 12.  Install furnace according to instructions in the Installation Instruc-
tions and Owner's Manual.
Note: If wall furnace is already installed, secure outer casing to 
unit.
 13.  Attach wire assembly to gas valve at the "TH" and "TH/TP" terminals 
on the Robertshaw valve.
    Attach wire assembly to gas valve at the "THERMO" terminals on 
the ITT valve.  If the wire assembly has two 1/4" (6mm) female 
connectors, the connectors should be cut off the wire assembly.  Strip 
and bare the wires and attach wires to the "THERMO" terminals. 
Note:  This remote bulb control is connected to the gas valve the 
same way as a wall thermostat. Any references made to the ther-
mostat in the lighting instructions would also apply to the remote 
INSTRUCTIONS
Note:  At the option of the owner, the remote bulb  control may be 
located on the left  or right side of the outer casing.
1.  Remove remote bulb control from the shipping carton.
2.  Remove outer casing assembly from shipping carton.
Note: If wall furnace is already installed, remove outer casing from 
unit and lay on floor with front side down.
3.  Attach wire assembly to remote bulb control.
4.  Carefully unwind capillary wire on remote bulb control.
5.  Remove (3) hole plugs from left or right side of outer casing where 
remote bulb control is to be installed.
6.   Mount remote bulb control to inside of outer casing with (2) No. 6-32 
x 1/4" (6mm)screws. 
TO VENT SAFETY
TO REMOTE BULB
T
O
THER
MOPIL
E
MODELS
GWT-25 RB, GWT-35 RB, GWT-50 RB
REMOTE BULB CONTROL INSTALLATION INSTRUCTIONS