Empire Products DVC-35IPT-1 Manuale Utente

Pagina di 24
Page 10
 
13119-6-0107
Locating Electric Supply
A 7/8”  diameter knockout is provided at the bottom of the left 
and right side panels. A three-prong (grounding) plug assembly is 
located within the control compartment (bottom) of the furnace. 
Please remove 7/8” knockout from appropriate side panel when 
routing plug assembly to an electrical outlet. Unit can be hard wired 
when recessed. Remove the 3 prong plug assembly and terminate 
inside the unit junction box.
Figure 7
Installation of Three-prong (Grounding) Plug Assembly
1. Disconnect  nylon  cap  on  3’  plug  assembly  from  nylon  plug 
on  wiring  harness.  Remove  3’  plug  assembly  from  control 
compartment (bottom) of the furnace.
2. Remove 7/8” knockout from appropriate side panel.
3. Insert nylon cap on 3’ plug assembly into the 7/8” hole in the 
side panel.
4. Connect nylon cap on 3’ plug assembly to nylon plug on the 
wiring harness.
5. Place 7/8” strain relief bushing around the cord of the 3’  plug 
assembly. Insert 7/8”  strain relief bushing into the 7/8”  hole in 
the side panel.
Attention! The 7/8” strain relief bushing is located within the same 
envelope as the Installation Instructions and Owner’s Manual.
Attaching Furnace to Wall
Place collar on four inch flue tube against outlet box. Align clearance 
holes on collar with screw holes in outlet box. Attach four inch flue 
tube to outlet box with four (4) 10 x 1/2” screws. 
Attention: Do not overtighten screws because outlet box must be 
able to move as flue tube expands and contracts.
Place collar on six inch air tube against air drop. Align clearance 
holes on collar with screw holes in air drop. Attach six inch air tube 
to air drop with eight (8) 10 x 1/2” screws.
Refer to Figure 5 for the location of the 7 1/2” diameter wall open-
ing for the furnace. After the wall opening has been located and 
cut, position flue outlet on furnace in center of wall opening. Insert 
tubes through wall opening. When attaching furnace to the wall 
remove that portion of baseboard and molding on the wall which is 
behind the furnace. Attach furnace to wall, at the outer casing top, 
with two (2) plastic expansion anchors provided and to floor, at the 
outer casing bottom, with two (2) 10 x 1 1/2” screws provided.
Figure 8
Using Plastic Expansion Anchors
  1.  After locating mounting holes, drill two (2) 5/16” diameter 
holes into the wall.
  2.  Insert  two  (2)  plastic  expansion  anchors  provided  into  the 
holes.
  3.  Tighten  two  (2)  10  x  1”  screws  provided  into  the  plastic 
expansion anchors. (See Figure 9)
Figure 9
Attention! The screw holes on the outer casing bottom are off-set 
the floor approximately 3/8”. Do not over-tighten screws and dis-
tort the off-set on the outer casing bottom. Distortion of the outer 
casing bottom will not allow the lower front panel to be attached 
to the furnace.