Empire Products FAW-40-1IP Manuale Utente

Pagina di 36
12427-4-0306
Page 2
The base referred to above does not mean the fire-proof base as used 
on wood stoves. The protection is for rugs that are extremely thick and 
light colored tile.
Installation in Residential Garages
Gas  utilization  equipment  in  residential  garages  shall  be  installed  so 
that all burners and burner ignition devices are located not less than 18" 
(457mm) above the floor.
Such equipment shall be located, or protected, so it is not subject to 
physical damage by a moving vehicle. 
Specifications
Introduction
Always consult your local Building Department regarding regulations, 
codes  or  ordinances  which  apply  to  the  installation  of  a  vented  wall 
furnace.
Instructions to Installer
1.  Installer  must  leave  instruction  manual  with  owner  after 
installation.
2.  Installer must have owner fill out and mail warranty card supplied 
with furnace.
3.  Installer should show owner how to start and operate furnace and 
thermostat.
Warning:
Any change to this furnace or its control can be dangerous. This 
is a heating appliance and any panel, door or guard removed 
for servicing an appliance must be replaced prior to operating 
the appliance.
General Information
This  series  is  design  certified  in  accordance  with American  National 
Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian Standards 
Association, as a Fan Type Vented Wall Furnace and must be installed 
according to these instructions.
Any alteration of the original design, installed other than as shown 
in  these  instructions  or  use  with  a  type  of  gas  not  shown  on  the 
rating plate is the responsibility of the person and company making 
the change.
Important
All correspondence should refer to complete Model No., Serial No. and 
type of gas.
Notice: During initial firing of this unit, its paint will bake out and smoke 
will occur. To prevent triggering of smoke alarms, ventilate the room in 
which the unit is installed.
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other combustible 
material other than wood flooring the appliance shall be installed on a metal 
or wood panel extending the full width and depth of the appliance. 
the flow of combustion and ventilation air.
•  DO keep the appliance area clear and free from combustible 
material, gasoline and other flammable vapors and liquids.
•  DO examine venting system periodically and replace damaged 
parts.
•  DO make a periodic visual check of pilot and burners. Clean 
and replace damaged parts.
•  CAUTION:  Pilot hole cover must be kept tightly closed during 
operation.
•  DO NOT use this heater if any part has been under water.  
Immediately call a qualified service technician to inspect the 
heater and to replace any part of the control system and any 
gas control which has been under water. 
•  This furnace must not be connected to a chimney flue serving 
a separate solid-fuel burning appliance.
• 
IMPORTANT: This furnace has a washable permanent type 
filter in the door which should be cleaned at  least once per 
year before the heating season. For dirty or high use areas 
more frequent cleaning is required.
  Due to high temperatures the appliance should be located out 
of traffic and away from furniture and draperies.
•  Children and adults should be alerted to the hazards of high 
surface temperatures and should stay away to avoid burns or 
clothing ignition.
•  Young children should be carefully supervised when they are 
in the same room as the appliance.
•  Clothing or other flammable material should not be placed on 
or near the appliance.
•  Any safety screen or guard removed for servicing an appliance 
must be replaced prior to operating the appliance.
•  Keep burner and control compartment clean.  
•  Installation and repair should be done by a QUALIFIED SER-
VICE PERSON.   The appliance should be inspected before 
use and at least  annually  by  a qualified service person.  More 
frequent cleaning may be required due  to excessive lint from 
carpeting, bedding materials, etc.  It is imperative that control 
compartments, burners  and circulating air passageways of the 
appliance be kept clean.
•  DO NOT put anything around the furnace that will obstruct 
THIS IS A HEATING APPLIANCE
DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANELS INSTALLED
.
Model
FAW-40SPP
FAW-40IP
Input BTU/HR (KW/H)
40,000 (11.7)
40,000 (11.7)
Height
72 1/2" (84.1mm) 72 1/2" (184.1mm)
Width
14 1/8" (35.9mm)
14 1/8" (35.9mm)
Depth
10 3/8" (26.4mm)
10 3/8" (26.4mm)
Gas Inlet Pipe
1/2" (12.7mm)
1/2" (12.7mm)
Vent Collar Type B Oval
4" (101mm)
4" (101mm)
CFM
275
275
Accessories
Register, side outlet, fixed register
SOR-1
Side outlet, 10" (254mm) 
  maximum extension, fixed register
SOK-1
Rear outlet, 10" (254mm) 
  maximum extension, adjustable register
ROK-1
Vent enclosure, 24" (609mm) 
  [for rooms up to 96 1/2" 2451mm) in height]
FVE-24
Vent enclosure, 34" (86cm) 
  [for rooms up to 106 1/2" (2705mm) in height]
FVE-34
Vent enclosure, 46" (1168mm) 
  [for rooms up to 118 1/2" (3009mm) in height]
FVE-46
Oval-to-Round flue adapter kit 4" (102mm)
DV-648