VENT SAFETY SHUTOFF SYSTEM
This appliance must be properly connected to a venting system.  
This appliance is equipped with a vent safety shutoff system.
Warning:    Operation  of  this  wall  furnace  when  not 
connected to a properly installed and maintained venting 
system or tampering with the vent safety shutoff system 
can result in carbon monoxide (CO) poisoning and possible 
death.
This furnace is equipped with a manual reset vent safety switch.  
The manual reset vent safety switch will cause gas flow to the main 
burner to "shut off" due to improper venting or a blocked flue.
To reset the manual reset vent safety switch:
1.  Remove outer casing.
2.  Depress manual reset button.  The manual reset vent safety 
switch is located on the draft diverter.
3.  Replace outer casing. 
If the manual reset vent safety switch continues to "shut off" the 
gas flow to the main burner a qualified service person must be 
contacted to inspect for improper venting, blockage in the vent 
pipe or the manual reset vent safety switch for being  defective.
   
Figure 8
PROPER MAIN BURNER FLAME
The correct flame will be a short blue inner flame with a much 
larger light blue outer flame.  The burner does not have a primary 
air adjustment.  The flame will be proper if the factory-set pressure 
and orifice are used.  After the furnace has begun operating, cleaning 
of the burner may be needed for proper flame, examine at least 2 
times per season.
To  clean  burner  ports,  disconnect  the  gas  supply  to  the  valve.  
Remove  the  burner  assembly  from  the  combustion  chamber.  
Remove pilot burner from main burner and then remove the main 
burner.  Force water into the ports and blow dry with vacuum 
cleaner air, or low pressure compressed air.
The correct flame will be blue, extending past the thermopile.  The 
flame will surround the thermopile just below its tip.
Natural gas pilots require adjusting when the inlet gas pressure is 
above 5" w.c. (1.245kPa).  Remove the pilot cover screw on the 
control valve and turn the adjustment screw clockwise to reduce 
flame.  Replace pilot cover screw to eliminate gas leaking at that 
control valve opening.
LP gas (propane) will not require adjustment.
After use, cleaning may be required for the proper flame.
Examine the pilot flame before and during each heating season. 
PROPER PILOT FLAME
Figure 9
Figure 10