FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:  If you do not follow these instructions exactly, a fire or explosion may result 
causing property damage, personal injury or loss of life.
A.   This  appliance  has  a  pilot  which  must  be  lighted  by 
hand.  When lighting the pilot, follow these instructions 
exactly.
B.   BEFORE LIGHTING  smell all around the appliance area 
for gas.  Be sure to smell next to the floor because some 
gas is heavier than air and will settle on the floor.
 
WHAT TO DO IF YOU SMELL GAS
•  Do not try to light any appliance.
•  Do not touch any electrical switch; 
 
do not use any phone in your building.
•  Immediately call your gas supplier from a neighbor's 
phone.  Follow the gas supplier's instructions.
•  If you cannot reach your gas supplier, call the fire 
department.
C.   Use only your hand to push in or turn the gas control 
knob.  Never use tools.  If the knob will not push in or turn 
by hand, don't try to repair it; call  a  qualified service 
technician.  Force or attempted repair may result in a fire 
or explosion.
D.   Do not use this appliance if any part has been under water.  
Immediately call a qualified service technician to inspect 
the appliance and to replace any part of the control system 
and any gas control which has been under water.
TO TURN OFF GAS TO APPLIANCE
1.   Set the thermostat to lowest setting.
2.   Turn off all electric power to appliance if service is to 
be performed (if applicable).
3.   Remove casing front assembly.
4.   Push in gas control knob slightly and turn clock-
wise  
 to "OFF." Do not force.
5.   Replace casing front assembly.
1.   STOP!   Read the safety information above.
2.  Set the thermostat to lowest setting.
3.  Turn  off  all  electric  power  to  the  appliance  (if  appli-
cable).
4.   Remove casing front assembly.
5.   Push  in  gas  control  knob  slightly  and  turn  clockwise 
 to "OFF".
 
 
NOTE:  Knob cannot be turned from "PILOT" to "OFF" 
unless knob is pushed in slightly.  Do not force.
6.   Wait ten (10) minutes to clear out any gas.  Then smell 
for gas, including near the floor.  If you smell gas, STOP! 
Follow "B" in the safety information above.  If you don't 
smell gas, go to the next step.
7.   Remove the pilot access cover located on the combustion 
chamber.  
8.   Find pilot - follow metal tube 
 
from gas control.  The pilot is 
 
behind the pilot access cover.
9.   Turn knob on gas control counterclockwise  
 to  
"PILOT."
10.  Push in control knob all the way and hold in.  Immediately 
light the pilot with the Piezo Pilot Ignitor or a match.  
Continue to hold the control knob in for about one (1) 
minute after the pilot is lit.  Release knob,  and it will pop 
back up.  Pilot should remain lit.  If it goes out, repeat 
steps 5 through 10.
  •  If  knob  does  not  pop  up  when  released,  stop  and 
immediately call your service technician or gas sup-
plier.  
  •  If the pilot will not stay lit after several tries, turn 
the gas control knob to "OFF" and call your service 
technician or gas supplier.  
11.  Replace pilot access cover.
12.  Turn  gas  control  knob  counterclockwise 
  to 
"ON."
13. Replace casing front assembly.
14.  Turn  on  all  electric  power  to  the  appliance  (if  appli-
cable).
15.  Set thermostat to desired setting.
16.  CAUTION:  Pilot access cover must be kept tightly closed 
during operation.
LIGHTING INSTRUCTIONS
LIGHTING INSTRUCTIONS