OPTIONAL BLOWER DRB-1
Installing Optional DRB-1 Blower
1.  Remove casing from front and heat shield
2.  When facing appliance, insert blower assembly into the left 
section of the casing (adjacent to the combustion chamber).
3.  Route cord set through opening in casing in bottom.  The opening 
in casing bottom is located beneath gas control.
4.  Align the two (2) screw holes on the inner side panel and the 
two (2) screw holes on casing back with the four (4) clearance 
holes on the blower assembly.  Attach blower assembly to the 
casing back and inner side panel with four (4) 10 x 1/2" screws 
provided.  The blower assembly must be attached first to the 
casing back and then to the casing side panel.
5.  Replace heat shield and casing front.
Attention:  Wiring harness on blower is factory assembled and 
installed.  If wiring harness becomes disassembled use the following 
steps to reassemble the wiring harness.
1.  Attach (1) pin terminal from black (hot) wire, smooth insulation 
on cord set to (1) socket terminal on fan control assembly.
2.  Attach  (1)  pin  terminal  from  black  (neutral)  wire,  ribbed 
insulation on cord set to (1) socket terminal from white (neutral) 
wire on motor.
3.  Attach (1) pin terminal on fan control assembly to (1) socket  
terminal from black (hot) wire on motor.
4.  Attach green ground wire beneath one of the #10 x 1/2" (13mm) 
screws on the blower housing.
Fan Control
The automatic fan control is located in the switch box.  The switch 
box is attached to the front of the blower assembly.   The switch 
box is adjacent to the combustion chamber.  The fan control is a 
non-adjustable automatic type.  The fan control will require between 
5 and 10 minutes of main burner operation before the fan control 
"closes" and activates the blower.  The blower will continue to run 
between 5 and 10 minutes after the main burner shuts off, before 
the fan control "opens" and deactivates the blower.
Wiring
The appliance, when installed, must be electrically grounded in 
accordance with local codes or, in the absence of local codes, with 
the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical 
Code, CSA C22.1, if an external electrical source is utilized. This 
appliance is equipped with a three-prong [grounding] plug for 
your protection against shock hazard and should be plugged 
directly into a properly grounded three-prong receptacle.  Do 
not cut or remove the grounding prong from this plug.  For an 
ungrounded receptacle, an adapter, which has two prongs and a 
wire for grounding, can be purchased, plugged into the ungrounded 
receptacle and its wire connected to the receptacle mounting screws.  
With this wire  completing the ground, the appliance cord plug can 
be plugged into the adapter and be electrically grounded.  
CAUTION:  Label  all  wires  prior  to  disconnection  when 
servicing  controls.    Wiring  errors  can  cause  improper 
and  dangerous  operation.    Verify  proper  operation  after 
servicing.  
WARNING:
Unplugging of blower accessory will not stop the heater 
from cycling.  To shut heater off:  Turn temperature dial  
or thermostat to lowest setting.  Turn knob on gas control 
to "OFF",   depressing slightly.  Do not force.
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS