Thermo Products GDM1-80N Manuale Utente

Pagina di 44
All installations and services must be performed by qualified service personnel. 
 
 
 
The area around the furnace must be kept free and clear of 
combustible materials, especially papers and rags.  
 
This furnace is not to be used as a construction heater.  
 
 
6.  Definitions of "combustible" and "non-combustible" materials as presented in the 
1999 version of the National Fuel Gas Code, ANSI Z223.1-1999/NFPA 70-1999, are 
as follows: 
 
a. Combustible material: 
“...materials made of or surfaced with wood, compressed 
paper, plant fibers, or other materials that are capable of 
being ignited and burned.  Such material shall be 
considered combustible even though flame proofed, fire-
retardant treated, or plastered.” 
b. Non-combustible material: 
“...material that is not capable of being ignited and 
burned; such as material consisting entirely of, or a 
combination of, steel, iron, brick, tiles, concrete, 
slate, asbestos, glass, and plaster.” 
 
This heating appliance must be installed with clearances to combustible material 
surfaces of not less than the minimum distances given below.  Also, allow ample 
clearances for servicing the furnace for easy access to the air filter, blower assembly, 
burner assembly, controls, and vent connections. 
 
MODELS GMD1-60N and GMD1-80N 
CLOSET 
ALCOVE 
FRONT 
BACK 
SIDES 
ROOF JACK 
VENT CONNECTOR 
TOP 
PLENUM SIDES 
TOP AND SIDES OF DUCT 
BOTTOM OF DUCT  
6” 
0” 
0” 
0” 
6” 
1” 
1” 
1” 
1” 
18” 
0” 
0” 
0” 
6” 
1” 
1” 
1” 
1”