Viking VGSB244T Manuale Utente

Pagina di 7
VGRT244T
24”W. Rangetop
GAS
Burner rating
• VGSB152T—Two grated
burners @ 15,000 BTU (4.4 kW)
Nat./13,500 BTU LP (4.0 kW)
• VGRT244T—Four grated
burners @ 15,000 BTU (4.4 kW)
Nat./13,500 BTU LP (4.0 kW)
• VGWT241T—One grated
burner @ 27,500 BTU (8.1 kW)
Nat./LP
• VGIB151T—One infrared grill
burner @ 21,500 BTU (6.3 kW)
Nat./20,000 BTU (5.9 kW) LP
• VGIB242T—Two infrared grill
burners, each @ 21,500 BTU
(6.3 kW) Nat./20,000 BTU (5.9
kW) LP
• Fixed piping installations 
o Check with local gas utility
company or with local codes
for instructions on installing
gas supply lines. All gas
connections should be made
by a competent technician
and in accordance with local
codes and or ordinances.  In
the absence of codes, the
installation must comply with
the National Fuel Gas Code
ANSI Z223.1.
o An installer-supplied gas
shut-off valve must be
installed in an easily
accessible location. All
installer-supplied parts must
conform to local codes.
o Must be isolated from the
gas supply piping system by
closing its individual manual
shut-off valve during any
pressure testing of that
system at test pressures
equal to or less than 1/2 psi
(3.5 kPa).
• Natural gas models (and
LP/propane, for VGWT only)
o Water column pressure
Operating pressure—4.0”
WCP
• 
Supply pressure of 6” –
14” WCP
If incoming pressure
exceeds 14” WCP, a step-
down regulator is required.
o Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 7/8” (2.2 cm) flare
adapter.
o If using a Viking GSH12
flexible hose, remove the
1/2” (1.3 cm) flare adapter
and attach hose to the 7/8”
(2.2 cm) male flare on the
regulator assembly.
• LP/propane models
o Water column pressure
Operating pressure—10”
WCP
Supply pressure of 11” –
14” WCP (for fixed piping
installations) 
If incoming pressure
exceeds 14” WCP, a step-
down regulator is required.
o Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 3/8” (0.95) flare adapter. 
• LP/propane tank installations 
o Water column pressure
Operating pressure—10”
WCP
o Includes high-capacity
hose/regulator assembly for
connection to a standard 5-
gal./20-lb. (approx. 12”
diameter/18”H.) LP/propane
gas cylinder equipped with a
Type 1, QCC-1 connector 
The cylinder connection
device must be compatible
with the Type 1, QCC-1
connector on the outdoor
cooking appliance. 
The cylinder must be
provided 
with a shut-
off valve terminating in an
LP/propane gas supply
cylinder valve outlet
specified. 
The cylinder supply system
must be arranged for
vapor withdrawal and
provided with a listed OPD
(overfilling prevention
device).
ELECTRICAL
• 9-volt DC battery for
electronic ignition (not
included?)
• Max. amp usage
o VGWT—0.08
PLUMBING
Not applicable
P L A N N I N G   A N D   D E S I G N   G U I D E
V I K I N G R A N G E . C O M       •       1 - 8 8 8 - V I K I N G 1
R E L E A S E D 1 2 / 1 / 0 7
© 2 0 0 7   V R C — INFORMATION SUBJECT TO CHANGE 
OUTDOOR—COOKING
Built-In Gas Side Burner, 24”W. Rangetop,
Wok/Cooker, & TruSear
Infrared Grillers
UTILITY
REQUIREMENTS
VGSB152T
Double Side Burner
VGWT241T
24”W. Wok/Cooker
VGIB151T
15”W. TruSear 
Infrared Griller
VGIB242T
24”W. TruSear 
Infrared Griller
Installation Requirements