Lopi Burner Manuale Utente

Pagina di 56
24
 Installation 
(for qualified installers only)
 
© Travis Industries 
4090717 
100-01225_000 
5.  Install the logs (see page 27). 
6.  Replace the glass. 
7.  Start the heater.   
8.  Leak test all gas joints.   
9.  Check the air shutter following the directions below. 
Air Shutter Adjustment  
Let the heater burn for fifteen minutes (make sure the logs and glass are in place).  The 
flames should be yellow with no sooting.  Adjust the air shutter, if necessary, to achieve the 
correct looking flame. 
Correct
Flames should be blue at the 
base, yellow-orange on the top.
If the flames are too tall or sooty on the 
ends, open the air shutter.
Not Enough Air
If the flames are all blue and 
short, close the air shutter.
Too Much Air
Swing the control cover down to 
access the air shutters.
Front Burner Air Shutter Control
(RED)
Right = Less Air
Left = More Air
Rear Burner Air Shutter Control
(GOLD)
Left = Less Air
Right = More Air
10.  Turn the flame adjust knob to its highest position - the flames should not contact the top of the firebox.  Check the flame 
on low position.  The flames should burn off of each burner hole.  If the heater does not work correctly, contact your Travis 
dealer for a remedy. 
11.  Give this manual to the home owner for future reference and fully explain operation of this heater.